Search
Now showing items 1-3 of 3
Magnetic induction tomography: Receiver circuit and its design criteria
(Penerbit UTM Press, 2013-07)
This paper discusses the receiver circuit and criteria for component selection towards the application of a real-time magnetic induction tomography system. Component selection plays an important role since image reconstruction ...
Magnetic induction tomography modeling in biological tissue imaging using two-port network technique
(International Frequency Sensor Association (IFSA), 2013)
Magnetic Induction Tomography (MIT) is a non-invasive and non-intrusive imaging technique which interested in passive electrical properties of a material that are permittivity, permeability and conductivity. MIT applies ...
Imaging of a metallic object using magnetic induction tomography
(International Frequency Sensor Association Publishing (IFSA), 2013-08)
This paper describes the metallic imaging results from magnetic induction tomography (MIT) hardware. Copper phantom, representing a high conductivity material, was placed into the measurement region of interest. The initial ...