Segmented capacitance tomography electrodes: A design and experimental verifications
(Institute of Electrical and Electronics Engineers (IEEE), 2012-05)
A segmented capacitance tomography system for real-time imaging of multiphase flows is developed and presented in this work. The earlier research shows that the electrical tomography (ECT) system is applicable in flow ...
An introduction of two differential excitation potentials technique in electrical capacitance tomography
(Elsevier B.V., 2012-06)
The investigation of this work is to analyse the sensitivity distributions using single and two differential excitation potentials techniques in order to improve the situation of: (1) non-uniform sensitivity distribution; ...
Sensor modeling for portable Electrical Capacitance Tomography system using simulation by COMSOL Multiphysics
(Innovative Computing, Information and Control (ICIC) International, 2012-10)
This work presents the development process for modeling a 16-segmented portable ECT (Electrical Capacitance Tomography) sensor (using FEM software package COMSOL Multiphysics). The physical sensors are 3D dimensional but ...
Optical tomography: Image improvement using mixed projection of parallel and fan beam modes
(Elsevier Ltd, 2013-07)
Mixed parallel and fan beam projection is a technique used to increase the quality images. This research focuses on enhancing the image quality in optical tomography. Image quality can be defined by measuring the Peak ...
Modelling ultrasonic sensor for gas bubble profiles characterization of chemical column
(Elsevier B.V., 2013)
In this paper, we present a modelling and experimental work to characterize gas bubble profiles in chemical column using a pair of ultrasonic sensor. The gas bubble profiles from 2.90 mm to 7.50 mm diameter are of interest ...