Now showing items 1-9 of 9

    • Edge detection algorithm for enhancement of linear back projection tomographic images 

      Muhammad Jaysuman, Pusppanathan; Mahdi Faramarzi; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr.; Fatin Aliah, Phang Abdullah, Dr.; Usman Ullah, Sheikh, Dr.; Loew,  Pei Ling, Dr.; Khairul Hamimah, Abas; Mohd Hafiz, Fazalul Rahiman, Dr.; Shafishuhaza, Sahlan (Penerbit UTM Press, 2014)
      Process tomography (PT) is a leading technique for multiphase flow measurement and flow monitoring systems in various fields. PT has the advantage of interpreting acquired measurement data and transforming it into visual ...
    • Image fusion using fuzzy logic pixel fusion for dual modality tomography system 

      Muhammad Jaysuman, Pusppanathan; Mahdi Faramarzi; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr. ; Fatin Aliah, Phang Abdullah, Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Anita, Ahmad, Dr.; Loew,  Pei Ling, Dr.; Khairul Hamimah, Abas (Penerbit UTM Press, 2014)
      Process tomography has been widely investigated and developed over time. The aim of this method is to measure the cross-sectional distribution of multiphase flow parameters based on its sensing technique. These single ...
    • Imaging of a metallic object using magnetic induction tomography 

      Muhammad Saiful Badri, Mansor; Zulkarnay, Zakaria; Ruzairi, Abdul Rahim, Prof. Dr. ; Ibrahim, Balkhis; Mohd Fahajumi, Jumaah; Mohd Zikrillah, Zawahir; Herlina, Abdul Rahim, Dr.; Loew, Pei Ling, Dr.; Khairul Hamimah, Abbas (International Frequency Sensor Association Publishing (IFSA), 2013-08)
      This paper describes the metallic imaging results from magnetic induction tomography (MIT) hardware. Copper phantom, representing a high conductivity material, was placed into the measurement region of interest. The initial ...
    • An introduction of two differential excitation potentials technique in electrical capacitance tomography 

      Elmy Johana, Mohamad, Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Leow, Pei Ling, Dr.; Mohd Hafiz Fazalul, Rahiman, Dr.; Omar Mohd Faizan, Marwah; Nor Muzakkir, Nor Ayob; Herlina, Abdul Rahim, Dr.; Fazlul Rahman, Mohd Yunus (Elsevier B.V., 2012-06)
      The investigation of this work is to analyse the sensitivity distributions using single and two differential excitation potentials techniques in order to improve the situation of: (1) non-uniform sensitivity distribution; ...
    • Magnetic induction tomography modeling in biological tissue imaging using two-port network technique 

      Muhammad Saiful Badri, Mansor; Mohd Fahajumi, Jumaah; Zulkarnay, Zakaria; Ruzairi, Abdul Rahim, Prof. Dr. ; Nor Muzakkir, Nor Ayob; Khairul Hamimah, Abbas; Siti Zarina, Mohd Muji; Sazali, Yaacob, Prof. Dr.; Herlina, Abdul Rahim, Dr.; Loew,  Pei Ling, Dr. (International Frequency Sensor Association (IFSA), 2013)
      Magnetic Induction Tomography (MIT) is a non-invasive and non-intrusive imaging technique which interested in passive electrical properties of a material that are permittivity, permeability and conductivity. MIT applies ...
    • Segmented capacitance tomography electrodes: A design and experimental verifications 

      Elmy Johana, Mohamad, Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Leow, Pei Ling, Dr.; Mohd Hafiz Fazalul, Rahiman, Dr.; Omar Mohd Faizan, Marwah; Nor Muzakkir, Nor Ayob (Institute of Electrical and Electronics Engineers (IEEE), 2012-05)
      A segmented capacitance tomography system for real-time imaging of multiphase flows is developed and presented in this work. The earlier research shows that the electrical tomography (ECT) system is applicable in flow ...
    • Sensor modeling for portable Electrical Capacitance Tomography system using simulation by COMSOL Multiphysics 

      Elmy Johana, Mohamad, Dr.; Muhammad Afiq Zimam, Mohamed; Ruzairi, Abdul Rahim, Prof. Dr.; Leow, Pei Ling, Dr.; Mohd Hafiz Fazalul, Rahiman, Dr.; Khairul Hamimah, Abas; Salinda, Bunyamin (Innovative Computing, Information and Control (ICIC) International, 2012-10)
      This work presents the development process for modeling a 16-segmented portable ECT (Electrical Capacitance Tomography) sensor (using FEM software package COMSOL Multiphysics). The physical sensors are 3D dimensional but ...
    • Study on wireless sensor based industrial tomography systems 

      Chiew, Loon Goh; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr.; Herlina, Abdul Rahim, Dr.; Muhammad Jaysuman, Pusppanathan; Mohd Hafiz, Fazalul Rahiman, Dr.; Loew,  Pei Ling, Dr.; Zulkarnay, Zakaria (International Frequency Sensor Association Publishing (IFSA), 2013)
      Wireless sensor technologies are promising in the field of industrial tomography system, to visualize the cross-sectional images of an industrial flow process. The aim of the paper is to review the technical and scientific ...
    • Ultrasonic tomography imaging for liquid-gas flow measurement 

      Muhammad Jaysuman, Pusppanathan; Nor Muzakkir, Nor Ayob; Fazlul Rahman, Mohd Yunus; Khairul Hamimah, Abbas; Herlina, Abdul Rahim, Dr.; Loew,  Pei Ling, Dr.; Ruzairi, Abdul Rahim, Prof. Dr. ; Fatin Aliah, Phang Abdullah, Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Zulkarnay, Zakaria (International Frequency Sensor Association (IFSA), 2013)
      This research was carried out to measure two-phase liquid - gas flow regime by using a dual functionality ultrasonic transducer. Comparing to the common separated transmitter-receiver ultrasonic pairs transducer, the dual ...