Now showing items 1-20 of 38

    • Application study on bubble detection in a metallic bubble column using electrical resistance tomography 

      Suzanna, Ridhuan Aw; Ruzairi, Abdul Rahim, Prof. Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Fazlul Rahman, Mohd Yunus; Naizatul Shima, Fadzil; Mohd Zikrillah, Zawahir; Mohd Fahajumi, Jumaah; Muhammad Jaysuman, Pusppanathan; Nor Muzakkir, Nor Ayob; Yasmin, Abdul Wahab; Salinda, Buyamin, Dr. (Penerbit UTM Press, 2014)
      Electrical RESISTANCE tomography (ERT) has been chosen as the field of study because of its advantages of being low COST, suitable for various kinds and sizes of pipes and vessels, having no radiation hazard, and being ...
    • Design and development fo a CCD based optical tomography measuring system for particle sizing identification 

      Mariani, Idroas; Ruzairi, Abdul Rahim; Mohd Hafiz, Fazalul Rahiman; M. N., Ibrahim; Green, R. G. (Elsevier Ltd, 2011-07)
      This research investigates the use of charge coupled device (abbreviated as CCD) linear image sensors in an optical tomographic instrumentation system used for sizing particles. Four CCD linear image sensors are configured ...
    • Design consideration for front-end system in ultrasonic tomography 

      Nor Muzakkir, Nor Ayob; Muhammad Jaysuman, Pusppanathan; Ruzairi, Abdul Rahim, Prof. Dr. ; Mohd Hafiz, Fazalul Rahiman, Dr.; Fazlul Rahman, Mohd Yunus; Salinda, Buyamin, Dr.; Intan Maisarah, Abd Rahim; Yusri, Md. Yunos, Dr. (Penerbit UTM Press, 2013)
      The hardware development of the ultrasonic tomography comprises three main parts; the sensor unit, electronic measurement circuits combined with a data acquisition system and finally the display unit. The research done is ...
    • Development of parallel and fan-shaped beam mixed-projection optical tomography 

      Siti Zarina, Mohd. Muji, Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Mohd Hafiz, Fazalul Rahiman; Yusry, Yunus; Zulkarnay, Zakaria; Nor Muzakkir, Nor Ayub (International Frequency Sensor Association Publishing (IFSA), 2012-05)
      Parallel and fan shaped beam are two common projections that had been used widely in optical tomography system. These projections never have been merged before in the process of tomography area. In this paper, some ...
    • Edge detection algorithm for enhancement of linear back projection tomographic images 

      Muhammad Jaysuman, Pusppanathan; Mahdi Faramarzi; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr.; Fatin Aliah, Phang Abdullah, Dr.; Usman Ullah, Sheikh, Dr.; Loew,  Pei Ling, Dr.; Khairul Hamimah, Abas; Mohd Hafiz, Fazalul Rahiman, Dr.; Shafishuhaza, Sahlan (Penerbit UTM Press, 2014)
      Process tomography (PT) is a leading technique for multiphase flow measurement and flow monitoring systems in various fields. PT has the advantage of interpreting acquired measurement data and transforming it into visual ...
    • Gas hold-up profiles determination by means of ultrasonic transducer 

      Mohd Hafiz, Fazalul Rahiman, Dr.; Ruzairi, Abdul Rahim, Prof. Dr. ; Herlina, Abdul Rahim, Dr.; Zulkarnay, Zakaria; Muhammad Jaysuman, Pusppanathan; Goh, Chiew Loon; Nasarudin, Ahmad; Yasmin, Abdul Wahab; Fazlul Rahman, Mohd Yunus (Penerbit UTM Press, 2014)
      This paper details a work carried out to measure gas hold-up profiles in a liquid column using a pair of ultrasonic transducer. The gas hold-up profiles from 1.85 mm to 7.7 mm diameter are of interest in this investigation. ...
    • Gas hold-up profiles measurement using ultrasonic sensor 

      Mohd Hafiz, Fazalul Rahiman; Ruzairi, Abdul Rahim, Prof. Dr.; Herlina, Abdul Rahim, Dr. (Institute of Electrical and Electronics Engineers (IEEE), 2011-02)
      In this letter, we present a work carried out to measure gas hold-up profiles in a liquid column using a pair of ultrasonic sensors. The gas hold-up profiles from 1.85 to 7.7 mm in diameter are of interest in this ...
    • The hardware design technique for ultrasonic process tomography system 

      Mohd Hafiz, Fazalul Rahiman, Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Herlina, Abdul Rahim, Dr.; Nor Muzakkir, Nor Ayob (International Frequency Sensor Association Publishing (IFSA), 2012-06)
      This paper describes a work carried out to design and development an ultrasonic process tomography system. The hardware design technique is of interest of this paper. A number of 32-ultrasonic transducers have been ...
    • Image fusion using fuzzy logic pixel fusion for dual modality tomography system 

      Muhammad Jaysuman, Pusppanathan; Mahdi Faramarzi; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr. ; Fatin Aliah, Phang Abdullah, Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Anita, Ahmad, Dr.; Loew,  Pei Ling, Dr.; Khairul Hamimah, Abas (Penerbit UTM Press, 2014)
      Process tomography has been widely investigated and developed over time. The aim of this method is to measure the cross-sectional distribution of multiphase flow parameters based on its sensing technique. These single ...
    • Initial study on optical fiber array to produce particle size information for hydraulic process 

      Yusri, Md. Yunos; Ruzairi, Abdul Rahim; Siti Zarina, Mohd Muji; Mohd Hafiz Fazalul Rahiman, Dr.; Muhammad Jaysuman, Pusppanathan (Springer Berlin Heidelberg, 2013-08)
      This paper presents the results of investigations carried out to determine the feasibility of using optical fibers to produce particle size information of hydraulic processes. The results have been obtained using a static ...
    • An introduction of two differential excitation potentials technique in electrical capacitance tomography 

      Elmy Johana, Mohamad, Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Leow, Pei Ling, Dr.; Mohd Hafiz Fazalul, Rahiman, Dr.; Omar Mohd Faizan, Marwah; Nor Muzakkir, Nor Ayob; Herlina, Abdul Rahim, Dr.; Fazlul Rahman, Mohd Yunus (Elsevier B.V., 2012-06)
      The investigation of this work is to analyse the sensitivity distributions using single and two differential excitation potentials techniques in order to improve the situation of: (1) non-uniform sensitivity distribution; ...
    • Measurement of the content of water using light penetration 

      Mohd Fahajumi, Jumaah; Mohd Zikrillah, Zawahir; Fazlul Rahman, Mohd Yunus; Ruzairi, Abdul Rahim, Prof. Dr.; Nor Muzakkir, Nor Ayob; Muhammad Saiful Badri, Mansor; Naizatul Shima, Fadzil; Zulkarnay, Zakaria; Mohd Hafiz, Fazalul Rahiman, Dr.; Mohd Ramzam, Abdul Manaf (Penerbit UTM Press, 2014)
      In this paper we use an electronic component to produce light which is applied in testing soft tissue penetration. We used bio tissue, a slice of apple, and non-bio tissue, paper. The voltage could be adjusted to brighten ...
    • Modelling ultrasonic sensor for gas bubble profiles characterization of chemical column 

      Mohd Hafiz, Fazalul Rahiman, Dr.; Ruzairi, Abdul Rahim, Prof. Dr. ; Herlina, Abdul Rahim, Dr.; Nor Muzakkir, Nor Ayob; Elmy Johana, Mohamad, Dr.; Zulkarnay, Zakaria (Elsevier B.V., 2013)
      In this paper, we present a modelling and experimental work to characterize gas bubble profiles in chemical column using a pair of ultrasonic sensor. The gas bubble profiles from 2.90 mm to 7.50 mm diameter are of interest ...
    • Multiphase ultrasonic tomography technique for homogeneous and Non-homogeneuos media identification 

      Mohd Rizal, Manan; Mohd Hafiz, Fazalul Rahiman; Sazali, Yaacob; Zulkarnay, Zakaria; Ruzairi, Abdul Rahim (Intel Tech Sdn. Bhd./Pac Tech Sdn. Bhd./Universiti Sains Malaysia (USM), 2009)
      Multiphase flow characterization is an important task for monitoring, measuring or controlling industrial processes. This can be done by means of process tomography. The use of tomographic techniques has been used within ...
    • Novel adjacent criterion method for improving ultrasonic imaging spatial resolution 

      Mohd Hafiz, Fazalul Rahiman, Dr; Ruzairi, Abdul Rahim, Prof. Dr.; Herlina, Abdul Rahim, Dr.; Nor Muzakkir, Nor Ayob (Institute of Electrical and Electronics Engineers (IEEE), 2012)
      In this letter, we present a novel approach for improving spatial resolution in ultrasonic tomography. The proposed technique modifies a Back-projection (BP) algorithm in reconstructing tomography images. We used 32-ultrasonic ...
    • Optical tomography hardware development for solid gas measurement using mixed projection 

      Siti Zarina, Mohd Muji; Chiew, Loon Goh; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr. ; Mohd Hafiz, Fazalul Rahiman, Dr.; Herlina, Abdul Rahim, Dr.; Muhammad Jaysuman, Pusppanathan; Naizatul Shima, Mohd Fadzil (Elsevier Ltd, 2013-10)
      The ability to implement fan beam projection in parallel view in an optical tomography setup is one of the novelties of this research. This design involves a sensor jig specifically designed for parallel applications that ...
    • Optical tomography system based on charge-coupled device linear image sensors: Particle size measurement 

      Idroas, M.; Ruzairi, Abdul Rahim; Mohd Hafiz, Fazalul Rahiman; Ibrahim, M. N. (Elsevier B.V, 2011-08)
      This paper discussed an optical tomography system based on charge-coupled device (CCD) linear image sensors. The developed system consists of a lighting system, a measurement section and a data acquisition system. Four CCD ...
    • Optical tomography system based on charge-coupled device linear image sensors: Particle size measurement 

      Mariani, Idroas; Ruzairi, Abdul Rahim; Mohd Hafiz, Fazalul Rahiman; M. N., Ibrahim (Elsevier B.V., 2011-08)
      This paper discussed an optical tomography system based on charge-coupled device (CCD) linear image sensors. The developed system consists of a lighting system, a measurement section and a data acquisition system. Four CCD ...
    • Optical tomography: A review on sensor array, projection arrangement and image reconstruction algorithm 

      Siti Zarina, Mohd. Muji; Ruzairi, Abdul Rahim; Mohd Hafiz, Fazalul Rahiman; Shafishuhaza, Sahlan; Mohd Fadzli, Abdul Shaib; Muhammad, Jaysuman; Elmy Johana, Mohamad (Kyushu Tokai University, 2011-07)
      This paper reviews previous research on sensor arrays, projection arrangements and image reconstruction algorithms of optical tomography for industrial processes. These include the review of sensor selection and projection ...
    • Optical tomography: Image improvement using mixed projection of parallel and fan beam modes 

      Siti Zarina, Mohd Muji; Ruzairi, Abdul Rahim, Prof. Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Zarina, Tukiran; Nor Muzakkir, Nor Ayob; Elmy Johana, Mohamad, Dr.; Muhammad Jaysuman, Pusppanathan (Elsevier Ltd, 2013-07)
      Mixed parallel and fan beam projection is a technique used to increase the quality images. This research focuses on enhancing the image quality in optical tomography. Image quality can be defined by measuring the Peak ...