Now showing items 1-13 of 13

    • Application study on bubble detection in a metallic bubble column using electrical resistance tomography 

      Suzanna, Ridhuan Aw; Ruzairi, Abdul Rahim, Prof. Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Fazlul Rahman, Mohd Yunus; Naizatul Shima, Fadzil; Mohd Zikrillah, Zawahir; Mohd Fahajumi, Jumaah; Muhammad Jaysuman, Pusppanathan; Nor Muzakkir, Nor Ayob; Yasmin, Abdul Wahab; Salinda, Buyamin, Dr. (Penerbit UTM Press, 2014)
      Electrical RESISTANCE tomography (ERT) has been chosen as the field of study because of its advantages of being low COST, suitable for various kinds and sizes of pipes and vessels, having no radiation hazard, and being ...
    • Design consideration for front-end system in ultrasonic tomography 

      Nor Muzakkir, Nor Ayob; Muhammad Jaysuman, Pusppanathan; Ruzairi, Abdul Rahim, Prof. Dr. ; Mohd Hafiz, Fazalul Rahiman, Dr.; Fazlul Rahman, Mohd Yunus; Salinda, Buyamin, Dr.; Intan Maisarah, Abd Rahim; Yusri, Md. Yunos, Dr. (Penerbit UTM Press, 2013)
      The hardware development of the ultrasonic tomography comprises three main parts; the sensor unit, electronic measurement circuits combined with a data acquisition system and finally the display unit. The research done is ...
    • Edge detection algorithm for enhancement of linear back projection tomographic images 

      Muhammad Jaysuman, Pusppanathan; Mahdi Faramarzi; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr.; Fatin Aliah, Phang Abdullah, Dr.; Usman Ullah, Sheikh, Dr.; Loew,  Pei Ling, Dr.; Khairul Hamimah, Abas; Mohd Hafiz, Fazalul Rahiman, Dr.; Shafishuhaza, Sahlan (Penerbit UTM Press, 2014)
      Process tomography (PT) is a leading technique for multiphase flow measurement and flow monitoring systems in various fields. PT has the advantage of interpreting acquired measurement data and transforming it into visual ...
    • Electrical resistance tomography: a review of the application of conducting vessel walls 

      Suzanna, Ridzuan Aw; Ruzairi, Abdul Rahim; Mohd Hafiz, Fazalul Rahiman; Fazlul Rahman, Mohd Yunus; Goh, Chiew Loon (Elsevier, 2014-03)
      Despite decades of research, the study on tomography continues to be a subject of great scientific interest. Amongst all the kinds of tomography available, electrical resistance tomography (ERT) has been chosen as the field ...
    • Gas hold-up profiles determination by means of ultrasonic transducer 

      Mohd Hafiz, Fazalul Rahiman, Dr.; Ruzairi, Abdul Rahim, Prof. Dr. ; Herlina, Abdul Rahim, Dr.; Zulkarnay, Zakaria; Muhammad Jaysuman, Pusppanathan; Goh, Chiew Loon; Nasarudin, Ahmad; Yasmin, Abdul Wahab; Fazlul Rahman, Mohd Yunus (Penerbit UTM Press, 2014)
      This paper details a work carried out to measure gas hold-up profiles in a liquid column using a pair of ultrasonic transducer. The gas hold-up profiles from 1.85 mm to 7.7 mm diameter are of interest in this investigation. ...
    • Image fusion using fuzzy logic pixel fusion for dual modality tomography system 

      Muhammad Jaysuman, Pusppanathan; Mahdi Faramarzi; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr. ; Fatin Aliah, Phang Abdullah, Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Anita, Ahmad, Dr.; Loew,  Pei Ling, Dr.; Khairul Hamimah, Abas (Penerbit UTM Press, 2014)
      Process tomography has been widely investigated and developed over time. The aim of this method is to measure the cross-sectional distribution of multiphase flow parameters based on its sensing technique. These single ...
    • An introduction of two differential excitation potentials technique in electrical capacitance tomography 

      Elmy Johana, Mohamad, Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Leow, Pei Ling, Dr.; Mohd Hafiz Fazalul, Rahiman, Dr.; Omar Mohd Faizan, Marwah; Nor Muzakkir, Nor Ayob; Herlina, Abdul Rahim, Dr.; Fazlul Rahman, Mohd Yunus (Elsevier B.V., 2012-06)
      The investigation of this work is to analyse the sensitivity distributions using single and two differential excitation potentials techniques in order to improve the situation of: (1) non-uniform sensitivity distribution; ...
    • Measurement of the content of water using light penetration 

      Mohd Fahajumi, Jumaah; Mohd Zikrillah, Zawahir; Fazlul Rahman, Mohd Yunus; Ruzairi, Abdul Rahim, Prof. Dr.; Nor Muzakkir, Nor Ayob; Muhammad Saiful Badri, Mansor; Naizatul Shima, Fadzil; Zulkarnay, Zakaria; Mohd Hafiz, Fazalul Rahiman, Dr.; Mohd Ramzam, Abdul Manaf (Penerbit UTM Press, 2014)
      In this paper we use an electronic component to produce light which is applied in testing soft tissue penetration. We used bio tissue, a slice of apple, and non-bio tissue, paper. The voltage could be adjusted to brighten ...
    • A review of tomography system 

      Juliza, Jamaludin; Mohd Zikrillah, Zawahir; Ruzairi, Abdul Rahim, Prof. Dr. ; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Suzzana, Muhammad Ridzuan Aw; Naizatul Shima, Mohd Fadzil; Zulkarnay, Zakaria; Mohd Hafiz, Fazalul Rahiman, Dr. (Penerbit UTM Press, 2013)
      Tomography system is a method that being used to reconstruct a cross sectional image in vessel or pipeline. This method is widely used in medical and industrial fields. The aim of this paper is to provide an overview of ...
    • Small gas component detection using ultrasonic transmission-mode tomography system 

      Nor Muzakkir, Nor Ayob; Muhammad Jaysuman, Pusppanathan; Ruzairi, Abdul Rahim, Prof. Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Fazlul Rahman, Mohd Yunus; Zulkarnay, Zakaria; Goh, Chiew Loon; Salinda, Buyamin, Dr.; Nasarudin, Ahmad; Yusri, Md. Yunos, Dr.; Norhaliza, Abdul Wahab, Assoc. Prof. Dr. (Penerbit UTM Press, 2014)
      This paper presents the development of an ultrasonic transmission-mode tomography system for the detection of small gas components by using higher frequency ultrasonic transducers. The selection of the transducer is important ...
    • Study and Design of an Ultrasonic Flow Tomographic Front-End Multi Level Measurement System 

      Goh, Chiew Loon; Ruzairi, Abdul Rahim, Prof. Dr. ; Suzanna, Ridhuan Aw; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Mohd Hafiz, Fazalul Rahiman, Dr.; Anita, Ahmad, Dr.; Nasarudin, Ahmad; Khairul Hamimah, Abas (Penerbit UTM Press, 2014)
      With the rapid evolution of electro-acoustical technology, ultrasonic tomography has made considerable progress in industry. An ultrasonic tomography system provides non-invasive and non-intrusive flow visualisation that ...
    • Study of the effect of brightness after penetration of light from a lens 

      Mohd Fahajumi, Jumaah; Mohd Zikrillah, Zawahir; Fazlul Rahman, Mohd Yunus; Ruzairi, Abdul Rahim, Prof. Dr.; Nor Muzakkir, Nor Ayob; Muhammad Saiful Badri, Mansor; Naizatul Shima, Mohd Fadzil; Zulkarnay, Zakaria; Mohd Hafiz, Fazalul Rahiman, Dr. (Penerbit UTM Press, 2013)
      There are many types of component that are able to produce light and the light is produced based on the angle and wavelength of the lens. Light penetration depends on the type of material used. The tests are done using ...
    • Ultrasonic tomography imaging for liquid-gas flow measurement 

      Muhammad Jaysuman, Pusppanathan; Nor Muzakkir, Nor Ayob; Fazlul Rahman, Mohd Yunus; Khairul Hamimah, Abbas; Herlina, Abdul Rahim, Dr.; Loew,  Pei Ling, Dr.; Ruzairi, Abdul Rahim, Prof. Dr. ; Fatin Aliah, Phang Abdullah, Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Zulkarnay, Zakaria (International Frequency Sensor Association (IFSA), 2013)
      This research was carried out to measure two-phase liquid - gas flow regime by using a dual functionality ultrasonic transducer. Comparing to the common separated transmitter-receiver ultrasonic pairs transducer, the dual ...