• Login
    View Item 
    •   DSpace Home
    • Journal Articles
    • International Journal of Nanoelectronics and Materials (IJNeaM)
    • View Item
    •   DSpace Home
    • Journal Articles
    • International Journal of Nanoelectronics and Materials (IJNeaM)
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Robust design of Kretschmann Plasmonic PCW-based integrated biosensor circuit

    Thumbnail
    View/Open
    Robust Design of Kretschmann Plasmonic PCW-based Integrated.pdf (1.117Mb)
    Date
    2019-04
    Author
    Kalaivani, A. Tarumaraja
    Menon, P. Susthitha
    Burhanuddin Yeop, Majlis
    Apte, Prakash R.
    Metadata
    Show full item record
    Abstract
    This paper presents the design optimization of an Integrated Biosensor Circuit (IBC) which utilizes graphene-based plasmonic Photonic Crystal Waveguide (PCW). The effects of 5 input signals, 4 control factors and 1 noise factor were investigated using Taguchi's dynamic L9 orthogonal array where the input signals are linearly related to the output response. The focus is to find the best combination of the parameters to achieve the best linearity insensitive to noise and obtain a robust design of the IBC. The input signals are based on the Refractive Index (RI) of glucose concentration in urine which ranges from 1.335 to 1.341. The control factors of the IBC are the PCW length (μm) – Factor A, the waveguide Bragg grating (WBG) length (μm) – Factor B, the modulator P length (μm) – Factor C, and the modulator Q length (μm)-Factor D, whereas the noise factor is the delta temperature of modulator Q where each factor was evaluated at 3 level values. Taguchi’s Higher-the-Better signal-to-noise (S/N) ratio was used to maximize the Free Spectral Range (FSR) of the IBC’s reflection output power which will directly increase the IBC’s biosensing sensitivity. The dominant control factors were identified as the PCW length (43% factor effect) and the WBG_2 length (22% factor effect). Upon dynamic Taguchi optimization, the FSR of the IBC improved by 0.62 dB for S/N ratio for linearity, the best control factors is A1B1C1D2, and the IBC’s sensitivity improved to 8.86μm/RIU for detection of glucose concentration in urine.
    URI
    http://dspace.unimap.edu.my:80/xmlui/handle/123456789/59908
    Collections
    • International Journal of Nanoelectronics and Materials (IJNeaM) [336]

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback
     

     

    Browse

    All of UniMAP Library Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback