Show simple item record

dc.contributor.authorH., Aimi Noorliyana
dc.contributor.authorMohd Zaheruddin, Kasmuin
dc.contributor.authorMd Fazlul, Bari
dc.contributor.authorSri Asliza, Md Amin
dc.contributor.authorKamarudin, Hussin, Brig. Jen. Dato' Prof. Dr.
dc.date.accessioned2010-08-18T07:44:06Z
dc.date.available2010-08-18T07:44:06Z
dc.date.issued2009-06-20
dc.identifier.citationp.47-50en_US
dc.identifier.urihttp://dspace.unimap.edu.my/123456789/8827
dc.descriptionMalaysian Technical Universities Conference on Engineering and Technology organized by Universiti Malaysia Pahang in collaboration with Universiti Tun Hussein Onn Malaysia, Universiti Teknikal Malaysia Melaka & Universiti Malaysia Perlis on June 20th - 22nd, 2009, at MS Garden Hotel, Kuantan, Pahang, Malaysia.en_US
dc.description.abstractThe Floatability of copper on the Modified Hallimond tube depend on lots of parameters such as dosage and types of collector, frother, air flow rate, flotation time, and pH value. All of this parameters give different effect on floatability. Collectors used for this study are 2- Mercaptobenzothiazole and Potassium n-Amyl Xanthate while frothers used are Methyl Isobutyl Carbinol and Propylene Glycol. pH of the mixture is varied using common pH modifier which is lime (CaO). The effects of air flow rate and flotation time were also studied. Overall, the result suggests that 2-Mercaptobenzothiazole (collector) is better than Potassium n-Amyl Xanthate at pH 10. Xanthate is very good recovering at pH 11-13 depends on kind of frother. As the dosage of the both collector increase, the percentage recovery of Cu also increase. Methyl Isobutyl Carbinol, (MIBC) is more effective than Propylene glycol as frother though the frother is not necessary in hallimond tube floatability test. As well, increasing in flotation time and air flow rate also will increase the percentage of recovery .Although the result showed copper recovery can be achieved on the Hallimond tube flotation, further test with different parameter have to be carried out to achieve the better result with lower cost and time.This test makes possible to get a better indication of how trends will be translated to a larger scale.en_US
dc.language.isoenen_US
dc.publisherUniversiti Malaysia Pahangen_US
dc.relation.ispartofseriesProceedings of the Malaysian Technical Universities Conference on Engineering and Technology (MUCEET) 2009en_US
dc.subjectFloatabilityen_US
dc.subjectModified Hallimond Tubeen_US
dc.subjectCopperen_US
dc.subjectMalaysian Technical Universities Conference on Engineering and Technology (MUCEET)en_US
dc.titleA study on floatability of copper using modified hallimond tubeen_US
dc.typeWorking Paperen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record