Show simple item record

dc.contributor.authorLee, Hoi Leong
dc.contributor.authorShahriman, Abu Bakar, Dr.
dc.contributor.authorSazali, Yaacob, Prof. Dr.
dc.contributor.authorZuradzman, Mohamad Razlan, Dr.
dc.contributor.authorWan Khairunizam, Wan Ahmad, Dr.
dc.contributor.authorZunaidi I.B
dc.contributor.authorCheng, Ee Meng, Dr.
dc.contributor.authorSiti Khadijah, Za'aba, Dr.
dc.contributor.authorShafriza Nisha, Basah, Dr.
dc.contributor.authorMohd Afendi, Rojan, Dr.
dc.contributor.authorSharifah Roohi, Syed Waseem Ahmad
dc.date.accessioned2014-05-30T02:33:04Z
dc.date.available2014-05-30T02:33:04Z
dc.date.issued2014-03
dc.identifier.citationAustralian Journal of Basic and Applied Sciences, vol. 8(4), Special 2014, pages 350-359en_US
dc.identifier.issn1991-8178
dc.identifier.urihttp://www.ajbasweb.com/old/2-ajbas_Special_2014.html
dc.identifier.urihttp://dspace.unimap.edu.my:80/dspace/handle/123456789/34893
dc.descriptionLink to publisher's homepage at http://www.aensiweb.com/en_US
dc.description.abstractElectrical bio-impedance measurement has great potential in many biomedical applications including vein graft surveillance. Studies have shown that thrombosis was the major cause of the vein graft failure. The meticulous skills of the surgeon and effective postoperative surveillance of vein graft remain the cornerstones of clinical success in the current surgical management of vein graft survival. Vascular blood flow is the key clinical indicators for the evaluation of patency of the vein graft and ensuring the patient’s quality of life. In this work, electrical bio-impedance method has been proposed as an alternative to the existing surveillance method as it is non-invasive, portable, easy applicable in practice, fast response, radiation free, and required only low-cost instrumentation. It was employed to measure pulsatile changes in longitudinal bio-impedance to quantify arterial blood flow and blood volume. We expect that by measuring the changes in tissue bio-impedance which can be used to evaluate important peripheral hemodynamic, it allows the detection of early stage stenosis within vascular and vein graft as well as estimate its severity with predetermined normative data provided.en_US
dc.language.isoenen_US
dc.publisherAmerican-Eurasian Network for Scientific Information (AENSI)en_US
dc.subjectElectrical bioimpedanceen_US
dc.subjectNon-invasiveen_US
dc.subjectVein graft surveillanceen_US
dc.subjectFingeren_US
dc.subjectHemodynamicen_US
dc.titleIn vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance methoden_US
dc.typeArticleen_US
dc.contributor.urlhoileong89@gmail.comen_US
dc.contributor.urlshahriman@unimap.edu.myen_US
dc.contributor.urls.yaacob@unimap.edu.myen_US
dc.contributor.urlzuradzman@unimap.edu.my.en_US
dc.contributor.urlkhairunizam@unimap.edu.myen_US
dc.contributor.urlemcheng@unimap.edu.myen_US
dc.contributor.urlkhadijah@unimap.edu.myen_US
dc.contributor.urlshafriza@unimap.edu.myen_US
dc.contributor.urlafendirojan@unimap.edu.myen_US
dc.contributor.urlroohi@medic.upm.edu.myen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record