The fabrication of heparin imprinted fiber membrane using electrospinning
Abstract
The studies of the fabrication of Heparin Imprinted Fiber membrane using Electrospinning was presented and investigated. This studies is about electrospinning
method use to produce membrane from Polyvinylidene fluoride (PVDF) sample.
Electrospinning is a new technique to prepare and produce polymer membrane. The
sample of PVDF needs to mixed into Acetone and Dimethylfluorine (DMF) with certain
ratio. The mixing need to stir for 3 hours at 600C temperature. The solution was mixed
with MIP or NIP in Dichloromethane (DCM) for 2hours at room temperature before
undergo electrospinning. The parameter changes for electrospinning process are
concentration of polymer solution and applied voltage. The samples that undergo
electrospinning will characterize by using Scanning Electron Microscopy (SEM). SEM
is functional to see the morphology analysis of membrane. Fourier Transform
Spectroscopy (FTIR) was use determine the surface of functional group of MIM and
NIM membranes. From, Thermogravimetric Analysis (TGA), the changes in chemical
and physical properties of the membranes was expected. The Batch Binding analysis
was investigated by using Varian Cary 50 UV-Visible Spectrophotometer at wavelength
250 nm towards MIM and NIM. The analysis show that the MIM absorbance and
amount of template rebound (Qaverage) was higher than NIM. The standard calibration
curve was used as guide to compare both of samples