    Study on mechanical characterization plastics waste as coarse aggregate (PWCA) for concrete

    Thumbnail
    View/Open
    Referrences and Appendix.pdf (200.0Kb)
    Conclusion.pdf (54.42Kb)
    Results and discussion.pdf (772.0Kb)
    Methodology.pdf (1.038Mb)
    Literature review.pdf (96.61Kb)
    Introduction.pdf (108.2Kb)
    Abstract, Acknowledgement.pdf (82.63Kb)
    Date
    2008-05
    Author
    Rozaimah Ramly
    Metadata
    Show full item record
    Abstract
    Quantities of plastics waste have been increased these recent years due to the boost in industrialization and the rapid improvement in the standard of living. In Malaysia, most of plastics waste is abandoned and not recycled. This situation causes serious problems such as wastage of natural resources and environmental pollution. Polymer products such as synthetic fibers, plastics and rubber belong to petrochemical compound and uneasily degrade in the natural environment. Plastic materials are not easily biodegradable even after a long period. In fact wide variety of waste materials can be utilized as inert in cement matrix. In this research, trash bag plastics are used as plastics waste as coarse aggregate (PWCA). The aim of this work is to study the properties and mechanical characterization of plastics waste as the replacement of coarse aggregate in concrete. Heating process were done at five different temperature; 160°C, 170°C,180°C, 190°C and 200°C . Four compositions of coarse aggregate with different crushed stone: PWCA waste ratios were used that are 0:100, 20:80, 40:60, and 100:0 by volumetric method. The comparisons of conventional concrete with PWCA were investigated depends on compressive and flexural testing. 100 % PWCA showed The compressive strength was measured after 28 days and it was found that the PC is suitable for nonstructural usage. As for cost analysis, the results showed that the PC is more cost effective than conventional concrete.
    URI
    http://dspace.unimap.edu.my/123456789/3271
    Collections
    • School of Materials Engineering (FYP) [338]

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback
     

     

    Browse

    All of UniMAP Library Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback