Search
Now showing items 11-18 of 18
Low cost detection of pH and its effect on the capacitive behavior of micro-gap sensor
(Trans Tech Publications, 2014)
The article describes the fabrication and characterization of silver microgap sensor on silicon substrate. By employing cheap photolithography process the proposed microgap sensor has been fabricated. The silver microgap ...
Conventional photolithography and process optimization of pattern- size expansion technique for nanogap biosensor fabrication
(Trans Tech Publications, 2014)
For a submicron photolithography process, there is little room for error. In this paper, an optimized technique for photoresist (PR) development is reported, to fabricate a nanogap biosensor for application in biomedical ...
Fabrication of nanostructure based biosensor for biomolecules detection
(Trans Tech Publications, 2014)
Lately, nanostructure based biosensor application has drawn a lot attention among fellow researchers because of speciality to detecting cell, tissue and even disease caused by viruses either from humans, animals or ...
Fabrication of silicon nanowires by electron beam lithography and thermal oxidation size reduction method
(Trans Tech Publications, 2014)
A simple method for the fabrication of silicon nanowires using Electron Beam Lithography (EBL) combined with thermal oxidation size reduction method is presented. EBL is used to define the initial silicon nanowires of ...
Reviewed immunosensor format using nanomaterial for tungro virus detection
(Trans Tech Publications, 2014)
Recently, nanomaterial based biosensor application has drawn a lot attention among researchers because of specialty to enhance the sensor signal for increasing the sensitivity for detecting and identification of pathogen, ...
Fabrication and characterization of IDE based sensor through conventional lithography method
(Trans Tech Publications, 2014)
This paper mainly illustrate regarding the fabrication process of IDE based sensor for bio-molecular detection process. Material that is utilized in this process is zinc oxide due to bio-compability and elevated electrical ...
Analysis of capillary filling in micro channels for passive fluid dynamics in Nano lab on chip domain
(Trans Tech Publications, 2014)
A fluid dynamics in a micro channel for analytical chemistry and different aspects of this type of flow for specific application has remained a long-acting problem in the last two decades considering its numerus applications ...
Nanobiosensor for the detection and quantification of pork adulteration in meatball formulation
(Taylor & Francis, 2014)
A 27-nucleotide AluI fragment of swine cytochrome b (cytb) gene was integrated to 3-nm diameter citrate–tannate-coated gold nanoparticles to fabricate a species-specific nanobiosensor. The biosensor was applied to authenticate ...