Show simple item record

dc.contributor.authorZahari, Taha
dc.contributor.authorMohd Azraai, Mohd Razman
dc.contributor.authorFaeiz Azizi, Adnan
dc.contributor.authorAnwar P.P. Abdul Majeed
dc.contributor.authorRabiu Muazu, Musa
dc.date.accessioned2018-03-07T03:20:56Z
dc.date.available2018-03-07T03:20:56Z
dc.date.issued2017
dc.identifier.citationMovement, Health & Exercise (MoHE), vol.6(1), 2017, pages 31-38en_US
dc.identifier.issn2231-9409 (Print)
dc.identifier.issn2289-9510 (Online)
dc.identifier.issnhttp://www.mohejournal.com/index.php/mohe
dc.identifier.urihttp://dspace.unimap.edu.my:80/xmlui/handle/123456789/52080
dc.descriptionLink to publisher's homepage at http://www.mohejournal.com/index.php/moheen_US
dc.description.abstractBackground: The accurate transfer of information on the athletes’ performance in any sport is essential in enhancing the performance and overall coaching process. The provision of such information is favourable only if it is reliable. A cost-effective golf putting monitoring device namely the Putt.It.In was developed for analysing a golfers’ putting performance. Objectives: This study aims to investigate the reliability of the instrument in measuring the backswing distance, front swing distance, clubhead speed, ideal front swing distance and swing angle. Methods: A semiprofessional golfer (30 years of age ± 5.0 years’ experience) executed four strokes repeatedly from a distance of 2 m and 1 m using a Ram Zebra Mallet putter on a PGM golf mat. The intra-class correlation (ICC) coefficient is employed to test the reliability of the device whilst the Kolmogorov/Smirnov test was utilised to further reaffirm the reliability of the application in measuring the aforementioned parameters over test re-test between first two strokes of 2 m distance and the last two strokes of 1 m distance. Results: The ICC reveals 0.98 and 0.96 for both test 1 and 2, as well as a Cronbach’s Alpha of 0.99 and 0.96, respectively suggesting excellent consistencies in the overall observations. Moreover, the Kolmogorov/Smirnov test re-test indicates that there is no significant difference between the first two 2 m strokes p > 0.05, and subsequent two 1 m strokes p > 0.05 highlighting its ability to recognise the pattern of the strokes applied in the four successive strokes. Conclusion: The Putt.It.In monitoring device is found to be reliable in measuring the backswing distance, front swing distance, clubhead speed, ideal front swing distance and swing angle. Professional and semi-professional golfers as well coaches could consider Putt.It.In device in monitoring strokes related parameters to enhance their performance due to its effectiveness in providing information on putting performance.en_US
dc.language.isoenen_US
dc.publisherKementerian Pendidikan Tinggi (KPT), Malaysiaen_US
dc.subjectGolfen_US
dc.subjectPuttingen_US
dc.subjectPutt.It.In Deviceen_US
dc.subjectReliability measurementsen_US
dc.subjectAthlete monitoringen_US
dc.titleThe development of the Putt.It.In monitoring device and the establishment of its reliability: a solution for putting-in analysis in Golfen_US
dc.typeArticleen_US
dc.contributor.urlanwarmajeed1983@gmail.comen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record