Show simple item record

dc.contributor.authorRuhana, Rozali
dc.date.accessioned2013-04-22T09:48:22Z
dc.date.available2013-04-22T09:48:22Z
dc.date.issued2012
dc.identifier.urihttp://dspace.unimap.edu.my/123456789/24425
dc.descriptionAccess is limited to UniMAP community.en_US
dc.description.abstractThe performances of waste cement which already exposure to environment condition was studied in term of compressive and flexural strength test. The specimens were prepared as mortar was cast in 50 mm cubes for compressive strength test and in 40mmx40mmx160mm prisms with mechanical compaction in two layers. Three specimens for each mix, curing period and parameters tests were prepared. This work initially deals with compressive strength characteristics, water absorption, X-Ray Fluorescence Analysis, cement sieve analysis and water absorption on mortar cured (standard curing) for 7, 14, 21 and 28 days. The curing work also has been to carry out. As the mix proportions for the specimen‟s water to cement ratio 0.5 were used. Each batch for all test specimens consist of (450 + 2) g of cement, (1350 + 5) g of sand, and (225 + 1) g of water. The compressive and flexural strength development of abandon Portland cement comparing with newly product of ordinary Portland cement (OPC) have been investigated. The specimens were prepared by using 50 x 50 mm cubes and 40 x 40 x 160 mm prisms mortar mould. Three types of cement were kept under different temperature (20°C, 32°C and 110°C). It is used to determine in which temperature the cement still could be utilized further. The result show that, the highly strength of cement mortar are affected by temperature 20°C while the cement that temperature 32°C which were kept in air-circulating condition give very lower strength. XRF result between newly product of Portland cement and abandon Portland cement shows the different on the composition element. The different compound of composition for each mineral has important individual characteristics. From the experiment result tells that by under different cement temperature those elements will change.en_US
dc.language.isoenen_US
dc.publisherUniversiti Malaysia Perlis (UniMAP)en_US
dc.subjectCementen_US
dc.subjectLimeen_US
dc.subjectMortaren_US
dc.subjectOrdinary Portland cement (OPC)en_US
dc.titleThe study of strength of abandon portland cementen_US
dc.typeLearning Objecten_US
dc.contributor.advisorMokhzani Khair Ishaken_US
dc.publisher.departmentSchool of Environmental Engineeringen_US


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record