Now showing items 1-10 of 10

    • Development of parallel and fan-shaped beam mixed-projection optical tomography 

      Siti Zarina, Mohd. Muji, Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Mohd Hafiz, Fazalul Rahiman; Yusry, Yunus; Zulkarnay, Zakaria; Nor Muzakkir, Nor Ayub (International Frequency Sensor Association Publishing (IFSA), 2012-05)
      Parallel and fan shaped beam are two common projections that had been used widely in optical tomography system. These projections never have been merged before in the process of tomography area. In this paper, some ...
    • Dielectric measurement techniques of biological tissue: A review on electrodes perspective 

      Ruzairi, Abdul Rahim, Prof. Dr.; Zulkarnay, Zakaria; Maliki, Ibrahim; Muhammad Saiful Badri, Mansor; Siti Zarina, Mohd. Muji, Dr.; Nor Muzakkir, Nor Ayub (International Frequency Sensor Association Publishing (IFSA), 2012-02)
      The aim of this paper is to review the techniques that have been developed in biological tissue dielectric measurement. This manuscript may give a clear picture on the history, development of the technology and also the ...
    • Initial study on optical fiber array to produce particle size information for hydraulic process 

      Yusri, Md. Yunos; Ruzairi, Abdul Rahim; Siti Zarina, Mohd Muji; Mohd Hafiz Fazalul Rahiman, Dr.; Muhammad Jaysuman, Pusppanathan (Springer Berlin Heidelberg, 2013-08)
      This paper presents the results of investigations carried out to determine the feasibility of using optical fibers to produce particle size information of hydraulic processes. The results have been obtained using a static ...
    • Optical tomography hardware development for solid gas measurement using mixed projection 

      Siti Zarina, Mohd Muji; Chiew, Loon Goh; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr. ; Mohd Hafiz, Fazalul Rahiman, Dr.; Herlina, Abdul Rahim, Dr.; Muhammad Jaysuman, Pusppanathan; Naizatul Shima, Mohd Fadzil (Elsevier Ltd, 2013-10)
      The ability to implement fan beam projection in parallel view in an optical tomography setup is one of the novelties of this research. This design involves a sensor jig specifically designed for parallel applications that ...
    • Optical tomography: A review on sensor array, projection arrangement and image reconstruction algorithm 

      Siti Zarina, Mohd. Muji; Ruzairi, Abdul Rahim; Mohd Hafiz, Fazalul Rahiman; Shafishuhaza, Sahlan; Mohd Fadzli, Abdul Shaib; Muhammad, Jaysuman; Elmy Johana, Mohamad (Kyushu Tokai University, 2011-07)
      This paper reviews previous research on sensor arrays, projection arrangements and image reconstruction algorithms of optical tomography for industrial processes. These include the review of sensor selection and projection ...
    • Optical tomography: Image improvement using mixed projection of parallel and fan beam modes 

      Siti Zarina, Mohd Muji; Ruzairi, Abdul Rahim, Prof. Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Zarina, Tukiran; Nor Muzakkir, Nor Ayob; Elmy Johana, Mohamad, Dr.; Muhammad Jaysuman, Pusppanathan (Elsevier Ltd, 2013-07)
      Mixed parallel and fan beam projection is a technique used to increase the quality images. This research focuses on enhancing the image quality in optical tomography. Image quality can be defined by measuring the Peak ...
    • Optical tomography: Velocity profile measurement using orthogonal and rectilinear arrangements 

      Ruzairi, Abdul Rahim; Yusri, Mohd Yunosa; Mohd Hafiz Fazalul, Rahiman; Siti Zarina, Mohd Muji; Chiam, Kok Thiam; Herlina, Abdul Rahim (Elsevier Ltd., 2012-03)
      In tomography applications, flow velocity is an important flow characteristic for analysis. Excessively high particle velocity will cause high energy consumption, severe pipeline wear and particle degradation. This paper ...
    • A review of the optical tomography system 

      Juliza, Jamaludin; Ruzairi, Abdul Rahim, Prof. Dr. ; Herlina, Abdul Rahim, Dr.; Naizatul Shima, Mohd Fadzil; Mohd Hafiz, Fazalul Rahiman, Dr.; Mohd Fahajumi, Jumaah; Siti Zarina, Mohd Muji, Dr.; Mohd. Amri, Md Yunus, Dr. (Penerbit UTM Press, 2014)
      Tomography is a method that has been used for image reconstruction in the medical and engineering fields. Optical tomography is one of the various methods APPLIED in tomography systems. This tomography method is widely ...
    • Review on interaction between electromagnetic field and biological tissues 

      Zulkarnay, Zakaria; Ruzairi, Abdul Rahim, Prof. Dr.; Lee, Pick Yern; Muhammad Saiful Badri, Mansor; Azian Azamimi, Abdullah; Sazali, Yaacob, Prof. Dr.; Siti Zarina, Mohd Muji (International Frequency Sensor Association (IFSA), 2012)
      The objective of this paper is to have a look on the interaction of electromagnetic field (EM) on biological tissue from the view of physiological and electrical engineering. The understanding of the phenomena in the ...
    • Ultrasonic tomography - image reconstruction algorithms 

      Mohd Hafiz, Fazalul Rahiman, Dr; Ruzairi, Abdul Rahim, Prof. Dr.; Herlina, Abdul Rahim, Dr.; Siti Zarina, Mohd Muji; Elmy Johana, Mohamad, Dr (International Journal of Innovative Computing, Information and Control (IJICIC), 2012-01)
      This paper focuses on image reconstruction algorithms for use in ultrasonic tomography. There are three types of algorithms namely Linear Back Projection, Hybrid Reconstruction and Hybrid Binary Reconstruction that are of ...