Now showing items 1-20 of 43

    • Application study on bubble detection in a metallic bubble column using electrical resistance tomography 

      Suzanna, Ridhuan Aw; Ruzairi, Abdul Rahim, Prof. Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Fazlul Rahman, Mohd Yunus; Naizatul Shima, Fadzil; Mohd Zikrillah, Zawahir; Mohd Fahajumi, Jumaah; Muhammad Jaysuman, Pusppanathan; Nor Muzakkir, Nor Ayob; Yasmin, Abdul Wahab; Salinda, Buyamin, Dr. (Penerbit UTM Press, 2014)
      Electrical RESISTANCE tomography (ERT) has been chosen as the field of study because of its advantages of being low COST, suitable for various kinds and sizes of pipes and vessels, having no radiation hazard, and being ...
    • Design and analysis of magnetic flux leakage capsule 

      Maliki, Ibrahim; Zulkarnay, Zakaria; Ali Aiman, Mustapha; Marisah, Norhasan; Mohd Nasir, Ayob; Ibrahim, Balkhis; Ruzairi, Abdul Rahim, Prof. Dr.  (International Frequency Sensor Association (IFSA), 2013-08)
      Magnetic flux leakage (MFL) is among the current in-line non-invasive popular technique applied in pipeline condition control and monitoring. This paper discussed on the design and development of magnetic flux leakage ...
    • Design and development fo a CCD based optical tomography measuring system for particle sizing identification 

      Mariani, Idroas; Ruzairi, Abdul Rahim; Mohd Hafiz, Fazalul Rahiman; M. N., Ibrahim; Green, R. G. (Elsevier Ltd, 2011-07)
      This research investigates the use of charge coupled device (abbreviated as CCD) linear image sensors in an optical tomographic instrumentation system used for sizing particles. Four CCD linear image sensors are configured ...
    • Design consideration for front-end system in ultrasonic tomography 

      Nor Muzakkir, Nor Ayob; Muhammad Jaysuman, Pusppanathan; Ruzairi, Abdul Rahim, Prof. Dr. ; Mohd Hafiz, Fazalul Rahiman, Dr.; Fazlul Rahman, Mohd Yunus; Salinda, Buyamin, Dr.; Intan Maisarah, Abd Rahim; Yusri, Md. Yunos, Dr. (Penerbit UTM Press, 2013)
      The hardware development of the ultrasonic tomography comprises three main parts; the sensor unit, electronic measurement circuits combined with a data acquisition system and finally the display unit. The research done is ...
    • Design of an infrared tomography system for detection of bubbles 

      Mohamad Aizat, Hashim; Yusri, Md Yunos; Ruzairi, Abdul Rahim, Prof. Dr.; Herlina, Abdul Rahim, Dr.; Muhammad Saiful Badri, Mansor; Nor Muzakkir, Nor Ayub (Penerbit UTM Press, Universiti Teknologi Malaysia., 2011-08)
      In this study, an optical process tomography with 2 orthogonal projections is being designed to be implemented at a vertical column modelled. The tomography system will be designed from the development of transducer pairs ...
    • Development of parallel and fan-shaped beam mixed-projection optical tomography 

      Siti Zarina, Mohd. Muji, Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Mohd Hafiz, Fazalul Rahiman; Yusry, Yunus; Zulkarnay, Zakaria; Nor Muzakkir, Nor Ayub (International Frequency Sensor Association Publishing (IFSA), 2012-05)
      Parallel and fan shaped beam are two common projections that had been used widely in optical tomography system. These projections never have been merged before in the process of tomography area. In this paper, some ...
    • Dielectric measurement techniques of biological tissue: A review on electrodes perspective 

      Ruzairi, Abdul Rahim, Prof. Dr.; Zulkarnay, Zakaria; Maliki, Ibrahim; Muhammad Saiful Badri, Mansor; Siti Zarina, Mohd. Muji, Dr.; Nor Muzakkir, Nor Ayub (International Frequency Sensor Association Publishing (IFSA), 2012-02)
      The aim of this paper is to review the techniques that have been developed in biological tissue dielectric measurement. This manuscript may give a clear picture on the history, development of the technology and also the ...
    • Edge detection algorithm for enhancement of linear back projection tomographic images 

      Muhammad Jaysuman, Pusppanathan; Mahdi Faramarzi; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr.; Fatin Aliah, Phang Abdullah, Dr.; Usman Ullah, Sheikh, Dr.; Loew,  Pei Ling, Dr.; Khairul Hamimah, Abas; Mohd Hafiz, Fazalul Rahiman, Dr.; Shafishuhaza, Sahlan (Penerbit UTM Press, 2014)
      Process tomography (PT) is a leading technique for multiphase flow measurement and flow monitoring systems in various fields. PT has the advantage of interpreting acquired measurement data and transforming it into visual ...
    • Electrical resistance tomography: a review of the application of conducting vessel walls 

      Suzanna, Ridzuan Aw; Ruzairi, Abdul Rahim; Mohd Hafiz, Fazalul Rahiman; Fazlul Rahman, Mohd Yunus; Goh, Chiew Loon (Elsevier, 2014-03)
      Despite decades of research, the study on tomography continues to be a subject of great scientific interest. Amongst all the kinds of tomography available, electrical resistance tomography (ERT) has been chosen as the field ...
    • Gas hold-up profiles determination by means of ultrasonic transducer 

      Mohd Hafiz, Fazalul Rahiman, Dr.; Ruzairi, Abdul Rahim, Prof. Dr. ; Herlina, Abdul Rahim, Dr.; Zulkarnay, Zakaria; Muhammad Jaysuman, Pusppanathan; Goh, Chiew Loon; Nasarudin, Ahmad; Yasmin, Abdul Wahab; Fazlul Rahman, Mohd Yunus (Penerbit UTM Press, 2014)
      This paper details a work carried out to measure gas hold-up profiles in a liquid column using a pair of ultrasonic transducer. The gas hold-up profiles from 1.85 mm to 7.7 mm diameter are of interest in this investigation. ...
    • The hardware design technique for ultrasonic process tomography system 

      Mohd Hafiz, Fazalul Rahiman, Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Herlina, Abdul Rahim, Dr.; Nor Muzakkir, Nor Ayob (International Frequency Sensor Association Publishing (IFSA), 2012-06)
      This paper describes a work carried out to design and development an ultrasonic process tomography system. The hardware design technique is of interest of this paper. A number of 32-ultrasonic transducers have been ...
    • Image fusion using fuzzy logic pixel fusion for dual modality tomography system 

      Muhammad Jaysuman, Pusppanathan; Mahdi Faramarzi; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr. ; Fatin Aliah, Phang Abdullah, Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Anita, Ahmad, Dr.; Loew,  Pei Ling, Dr.; Khairul Hamimah, Abas (Penerbit UTM Press, 2014)
      Process tomography has been widely investigated and developed over time. The aim of this method is to measure the cross-sectional distribution of multiphase flow parameters based on its sensing technique. These single ...
    • Imaging of a metallic object using magnetic induction tomography 

      Muhammad Saiful Badri, Mansor; Zulkarnay, Zakaria; Ruzairi, Abdul Rahim, Prof. Dr. ; Ibrahim, Balkhis; Mohd Fahajumi, Jumaah; Mohd Zikrillah, Zawahir; Herlina, Abdul Rahim, Dr.; Loew, Pei Ling, Dr.; Khairul Hamimah, Abbas (International Frequency Sensor Association Publishing (IFSA), 2013-08)
      This paper describes the metallic imaging results from magnetic induction tomography (MIT) hardware. Copper phantom, representing a high conductivity material, was placed into the measurement region of interest. The initial ...
    • Initial study on optical fiber array to produce particle size information for hydraulic process 

      Yusri, Md. Yunos; Ruzairi, Abdul Rahim; Siti Zarina, Mohd Muji; Mohd Hafiz Fazalul Rahiman, Dr.; Muhammad Jaysuman, Pusppanathan (Springer Berlin Heidelberg, 2013-08)
      This paper presents the results of investigations carried out to determine the feasibility of using optical fibers to produce particle size information of hydraulic processes. The results have been obtained using a static ...
    • An introduction of two differential excitation potentials technique in electrical capacitance tomography 

      Elmy Johana, Mohamad, Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Leow, Pei Ling, Dr.; Mohd Hafiz Fazalul, Rahiman, Dr.; Omar Mohd Faizan, Marwah; Nor Muzakkir, Nor Ayob; Herlina, Abdul Rahim, Dr.; Fazlul Rahman, Mohd Yunus (Elsevier B.V., 2012-06)
      The investigation of this work is to analyse the sensitivity distributions using single and two differential excitation potentials techniques in order to improve the situation of: (1) non-uniform sensitivity distribution; ...
    • Magnetic Flux Leakage (MFL) Capsule material selection and its robustness analysis in oil and gas pipeline 

      Maliki, Ibrahim; Zulkarnay, Zakaria; Ali Aiman, Mustapha; Surin, Dennis Desmond; Mohd Nasir, Ayob; Ibrahim, Balkhis; Ruzairi, Abdul Rahim, Prof. Dr.  (International Frequency Sensor Association (IFSA), 2013-08)
      This paper discussed on the material selection and its robustness analysis towards the design of magnetic flux leakage capsule that most applied in oil and gas pipeline. Magnetic Flux Leakage is among the most famous and ...
    • Magnetic induction tomography modeling in biological tissue imaging using two-port network technique 

      Muhammad Saiful Badri, Mansor; Mohd Fahajumi, Jumaah; Zulkarnay, Zakaria; Ruzairi, Abdul Rahim, Prof. Dr. ; Nor Muzakkir, Nor Ayob; Khairul Hamimah, Abbas; Siti Zarina, Mohd Muji; Sazali, Yaacob, Prof. Dr.; Herlina, Abdul Rahim, Dr.; Loew,  Pei Ling, Dr. (International Frequency Sensor Association (IFSA), 2013)
      Magnetic Induction Tomography (MIT) is a non-invasive and non-intrusive imaging technique which interested in passive electrical properties of a material that are permittivity, permeability and conductivity. MIT applies ...
    • Mathematical modelling of gas bubbles and oil droplets in liquid media using optical linear path projection 

      Ruzairi, Abdul Rahim; Yusri, Md Yunos; Mohd Hafiz, Fazalul Rahiman; Herlina, Abdul Rahim (Elsevier Ltd., 2010-05-05)
      This paper describes mathematical modelling of oil droplets and gas bubbles in water. The light sources that are discussed are visible light radiation and infrared radiation. Gas bubbles or oil droplets less than 1 mm ...
    • Measurement of the content of water using light penetration 

      Mohd Fahajumi, Jumaah; Mohd Zikrillah, Zawahir; Fazlul Rahman, Mohd Yunus; Ruzairi, Abdul Rahim, Prof. Dr.; Nor Muzakkir, Nor Ayob; Muhammad Saiful Badri, Mansor; Naizatul Shima, Fadzil; Zulkarnay, Zakaria; Mohd Hafiz, Fazalul Rahiman, Dr.; Mohd Ramzam, Abdul Manaf (Penerbit UTM Press, 2014)
      In this paper we use an electronic component to produce light which is applied in testing soft tissue penetration. We used bio tissue, a slice of apple, and non-bio tissue, paper. The voltage could be adjusted to brighten ...
    • Modelling ultrasonic sensor for gas bubble profiles characterization of chemical column 

      Mohd Hafiz, Fazalul Rahiman, Dr.; Ruzairi, Abdul Rahim, Prof. Dr. ; Herlina, Abdul Rahim, Dr.; Nor Muzakkir, Nor Ayob; Elmy Johana, Mohamad, Dr.; Zulkarnay, Zakaria (Elsevier B.V., 2013)
      In this paper, we present a modelling and experimental work to characterize gas bubble profiles in chemical column using a pair of ultrasonic sensor. The gas bubble profiles from 2.90 mm to 7.50 mm diameter are of interest ...