    Molarity model of mass transfer for extraction in rotating disc contactor (RDC) column

    Thumbnail
    View/Open
    Access is limited to UniMAP community (110.8Kb)
    Date
    2010-06-02
    Author
    Nurul Nadiya, Abu Hassan
    Jamalludin, Talib
    Normah, Maan
    Metadata
    Show full item record
    Abstract
    Mass transfer is a process that occurs in liquid-liquid extraction column. One of the equipment uses for the liquid-liquid extraction is the rotating disc contactor (RDC) column. In order to determine the concentration of the dispersed phase and also the concentration of the continuous phase of the rotating disc contactor column, a new mass transfer model is incorporated into the existing boundary approach of mass transfer model. A simulation is then being carried out. Comparison of the simulation result and the experimental data shows that the results are approaching each other.