Measuring the temperature variation along the length of a triple concentric tube heat exchanger
(Universiti Malaysia Perlis (UniMAP), 2009-04)
A triple concentric tube heat exchanger of approximately 4m length is fabricated using
stainless steel tubes of 2 inches (5.08cm), 3 inches (7.62cm) and 4 inches (10.16cm)
diameter respectively. The three different fluids ...
Analysis of heat exchanger concentric tube by Finite Element Method
(Universiti Malaysia Perlis, 2009)
The objective for this project is to study the performance of heat exchanger in parallel flow
and counter flow. This experiment using three different temperature of water like cold, hot