    Reliability study on surface water and drainage control system and the efficiency of GCL and GDL as capping system on Kuala Perlis landfill

    Thumbnail
    View/Open
    Reference and appendix.pdf (264.0Kb)
    Conclusion.pdf (194.1Kb)
    Results and discussion.pdf (330.0Kb)
    Methodology.pdf (216.3Kb)
    Literature review.pdf (132.5Kb)
    Introduction.pdf (206.8Kb)
    Abstract, Acknowledgement.pdf (294.7Kb)
    Date
    2012-05
    Author
    Siti Aminah, Md Saad
    Metadata
    Show full item record
    Abstract
    The objective of this study is to examine the characteristics of the surface water, drainage control system, and the landfill capping system on Kuala Perlis landfill. This study also aims to investigate the actions been taken or will be taken in ensuring the function of this landfill does not affecting the public health and surrounding environment along its operation particularly and for near future land use. This research will measure the quality of leachate on Kuala Perlis landfill and its effects to the surrounding environment. The leachates from landfill were tested for Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Ammoniacal Nitrogen (NH3-N) and heavy metal which were Zinc (Zn) and Chromium Hexavalent (Cr6+) from four different points within three weeks of sampling period. Based on the results, the average BOD concentration ranged from 15 mg/L to 44.8 mg/L while COD average concentration were between 130 mg/L and 4335.8 mg/L. Average NH3-N concentration ranged between 90 mg/L and 328.7 mg/L. For Zn concentration, the lowest value was 0.026 mg/L and the highest value was 0.240 mg/L while the average Cr6+ concentration ranged from 0.047 mg/L to 0.252 mg/L. For Kuala Perlis landfill, Geosynthetic Clay Liner (GCL) and Geosynthetic Drainage Layer (GDL) have been used as capping systems to control the surface water and, being as drainage systems.
    URI
    http://dspace.unimap.edu.my/123456789/24438
    Collections
    • School of Environmental Engineering (FYP) [640]

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback
     

     

    Browse

    All of UniMAP Library Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback