• Login
    View Item 
    •   DSpace Home
    • Final Year Project Papers & Reports
    • School of Environmental Engineering (FYP)
    • View Item
    •   DSpace Home
    • Final Year Project Papers & Reports
    • School of Environmental Engineering (FYP)
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Potential of ground sink heat pump for small scale air conditioning system

    Thumbnail
    View/Open
    Abstract, Acknowledgement.pdf (210.3Kb)
    Conclusion.pdf (188.8Kb)
    Introduction.pdf (112.8Kb)
    Literature review.pdf (408.0Kb)
    Methodology.pdf (361.8Kb)
    Reference and appendix.pdf (589.6Kb)
    Results and discussion.pdf (370.4Kb)
    Date
    2011-04
    Author
    Wan Nurfarzana, Wan Mazlan
    Metadata
    Show full item record
    Abstract
    In the pursuit of sustainable environment, systems with high efficiency and produce less pollution are brought into perspective. Geothermal would provide a solution for energy efficiency and an option of renewable energy. Ground Sink Heat Pump (GSHP) system is an air conditioning system that uses the Earth's ability to store heat in the ground and water thermal masses. In this project, it showed the comparison design installation between a GSHP system and an Air Source Heat Pump (ASHP) system which acts GSHP as an effective air-conditioner and eco-friendly, using natural characteristics of the Earth’s surface. The systems connected to a test room in School of Environmental Engineering UniMAP were designed and constructed for space cooling. The performance of GSHP and the ASHP system were experimentally determined. The power consumption for GSHP in the range in 0.21 to 0.46 kWh and for ASHP in the range 0.33 to 0,38 kWh has been consumed per day. Besides that, the sizing and costing of the proposed system had been determined. The test room and ground loop had been designed in size of the room 2 meter length, 2 meter high and 1 meter width. The GSHP system was operated and tested in during the cooling season in the School of Environmental Engineering UniMAP, which presents a great potential for commercialization of GSHP. Based on the results, it was proven that the potential of GSHP for small scale air conditioning system can be more efficient when some recommendation were added such as select the correct equipment, check site access for equipment to install a GSHP and others.
    URI
    http://dspace.unimap.edu.my/123456789/22895
    Collections
    • School of Environmental Engineering (FYP) [640]

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback
     

     

    Browse

    All of UniMAP Library Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback