• Login
    View Item 
    •   DSpace Home
    • The Library
    • Conference Papers
    • View Item
    •   DSpace Home
    • The Library
    • Conference Papers
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A modified chest leads for minimization of ventricular activity in electrocardiograms

    Thumbnail
    View/Open
    Access is limited to UniMAP community (768.2Kb)
    Date
    2012-02-27
    Author
    Sivaraman, J.
    Uma, G.
    Umapathy, M.
    Metadata
    Show full item record
    Abstract
    A very little information of the atrial depolarization and repolarization phase of the electrocardiogram is seen in normal and in any abnormal ECG’s. The observation of the electrical activity of the each atrium is critical in the case of the atrial arrthymias. Since, the conventional 12 lead ECG configuration views the electrical axis of the different anatomical space of the ventricles, much larger information about the atria is not well explained. The atrial activity seen in ECG trace is very less compared to the QRS complex and some of the atrial phase is obscured in the large ventricular activity. A modified chest lead system is proposed to provide more information about the electrical activity of the atria in normal subjects. ECG trace were recorded and analyzed simultaneously for the subjects with the proposed modified chest leads and the conventional bipolar limb leads in the CRO. The amplitude of the QRS complex in conventional bipolar limb leads was found to be 3.4V, 4.8V and 1.4V respectively and the Einthoven triangle were satisfied. In the modified chest lead ECG, the QRS complex was much reduced and found to be 0.6V. The duration of the atrial P wave was found to be 0.08sec and the total atrial complex was found to be 0.22 sec in the modified chest lead. A negative wave was found in the PR segment which is found to be non iso-electric and had duration of 0.14 sec claimed due to the atrial repolarisation wave.
    URI
    http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6178959
    http://dspace.unimap.edu.my/123456789/20722
    Collections
    • Conference Papers [2599]

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback
     

     

    Browse

    All of UniMAP Library Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback