Search
Now showing items 21-30 of 2460
Application-specific multichannel EEG data acquisition system for portable biomedical application
(Malaysian Technical Universities Network (MTUN), 2012-11-20)
This paper presents the design and construction of a low power application-specific EEG bio-potential multichannel
amplifier with high common mode rejection ratio (CMRR) and high input impedance. The bio-potential amplifier ...
Performance evaluation of SAC-OCDMA using direct detection techniques
(Universiti Malaysia Perlis (UniMAP), 2012-06-18)
In optical code division multiple access (OCDMA), noise give a big effect in degrading the performance of the system. Theoretically, direct detection technique can successfully suppressed or eliminate the dominant noise ...
Effects of winding angles in biaxial ultimate elastic wall stress (UEWS) tests of glass fibre reinforced epoxy (GRE) composite pipes
(Universiti Malaysia Perlis (UniMAP), 2013-03-26)
This paper presents an experimental investigation into the influence of winding angles in multiaxial ultimate elastic wall stress (UEWS) tests of glass-fibre reinforced epoxy (GRE) composite pipes. Currently, UEWS test is ...
A review of microfluidic sensing system for medical application
(Universiti Malaysia Perlis (UniMAP), 2012-06-18)
In this paper, we present about the preview paper of Microfluidic sensing system and simulation using COMSOL Multiphysics. Based on the basic Microfluidic system, pervious paper and work can help us to more understand and ...
Fabrication and characterization of 50 nm silicon nano-gap structures
(American Scientific Publishers, 2011-04)
A simple method for the fabrication of nano-gaps less than 50 nm by using conventional photolithography combined with patterned-size reduction techniques is presented. Silicon material is used to fabricate the nano-gap ...
Theoretical and experimental study towards fabrication of nanogap dielectric biosensor by reversed spacer lithography
(American Institute of Physics, 2010-03-11)
A reversed spacer patterning technology using a sacrificial layer and a chemical vapor deposition (CVD) spacer layer has been developed, and is demonstrated to achieve sub-50 nm structures with conventional dry etching. ...
Precise alignment of individual single-walled carbon nanotube using dielectrophoresis method for development and fabrication of pH sensor
(Hindawi Publishing Corporation, 2013)
Development and fabrication of single-walled carbon nanotube (SWNT) based pH sensor were reported. The precise alignment of individual SWNT using dielectrophoresis method between the two microgap electrodes was conducted, ...
Modeling development of a high-sensitivity escherichia coli O157:H7 detection based on SH SAW sensor
(Trans Tech Publications, 2014-04)
Surface acoustic waves based devices were initially developed for the telecommunication purpose such as signal filters and resonators. The acoustic energy is strongly confined on the surface of the surface acoustic waves ...
Tensile properties of polypropylene/cocoa pod husk biocomposites: Effect of maleated polypropylene
(Trans Tech Publications, 2013)
Polypropylene/Cocoa Pod Husk (PP/CPH) biocomposites with different maleated polypropylene (MAPP) content were prepared via melt blending process using Brabender Plastrograph mixer. The tensile strength and tensile modulus ...
The use of dielectric mixture equations to analyze the dielectric properties of a mixture of rubber tire dust and rice husks in a microwave absorber
(Progress in Electromagnetics Research (PIER), 2012)
A change in the relative proportions of a mixture of rubber tire dust and rice husks will cause a change in the mixture's electrical permittivity and its ability to absorb electromagnetic energy. An openended coaxial probe ...