    Development of Electrocardiogram (ECG) monitoring device

    Thumbnail
    View/Open
    Abstract,Acknowledgement.pdf (208.8Kb)
    Introduction.pdf (193.7Kb)
    Literature Review.pdf (365.7Kb)
    Methodology.pdf (425.7Kb)
    Results and Discussion.pdf (456.0Kb)
    Conclusion and Recommendation.pdf (177.4Kb)
    Refference and Appendics.pdf (706.9Kb)
    Date
    2015-12
    Author
    Amy Shikin, Andi Asdi
    Metadata
    Show full item record
    Abstract
    Heart related diseases such as Heart Disease, Stroke and other Cardiovascular Diseases are the leading killer diseases all over the world. Many devices are developed to detect early sign or symptoms of heart abnormalities. Electrocardiogram (ECG) is a graphic tracing of the electric current generated by the heart muscle during a heartbeat. It is used to detect the heart wave abnormality. The commercial ECG in the market is very costly, thus it is an advantage to be able to develop personal ECG monitoring device. Three electrodes which is placed on the right arm, left arm and the right leg are used to detect the heart wave on the skin instead of 12 electrode used clinically. The signal is amplified using instrumentation amplifier AD620. It is chosen for its high Common Mode Rejection Ratio (CMRR) and the gain from AD620 is 50.40 gain. Operational amplifier OP07 is used for a few circuit design which are right leg driven, band pass filter and also the level shifter. OP07 is chosen for its low noise. In this project, the designing of analog amplifier circuit was achieved. Function generator was used as an input signal as the alternative of the real heart wave. The analog amplifier circuit manage to amplify the voltage of the function generator. This indicate that when the real heart wave enters the amplifier circuit, it will also able to be amplified.
    URI
    http://dspace.unimap.edu.my:80/xmlui/handle/123456789/42550
    Collections
    • Faculty of Engineering Technology (FYP) [202]

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback
     

     

    Browse

    All of UniMAP Library Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback