    Performance of reinforced concrete wall panel with rubber tyre as sand replacement for IBS component

    Thumbnail
    View/Open
    Abstract, Acknowledgement.pdf (338.2Kb)
    Introduction.pdf (167.5Kb)
    Literature review.pdf (263.0Kb)
    Methodology.pdf (593.5Kb)
    Results and discussion.pdf (326.1Kb)
    Conclusion.pdf (151.9Kb)
    References and appendix.pdf (590.0Kb)
    Date
    2014-06
    Author
    Mohd Sukri, Zainal Abidin
    Metadata
    Show full item record
    Abstract
    Reinforced concrete wall panel is a component used in the design and structure of buildings as space dividers or as load bearing walls, especially for application in the Industrilized System (IBS). The use of rubber tyres on the vehicle at this time showed a sharply increase from year to year, eventually contributed to the waste rubber tyres of the vehicle. The objectives of this study to determine the engineering properties based on existing standards and patterns of cracking of reinforced concrete wall panel when a waste rubber tyres replace the sand in concrete mix for IBS components. Percentages of crumb rubber tyres replace sand in the reinforced concrete wall panels are 0 % (control) and 2.5 %. The size reinforced concrete wall panel sample used is 750 mm x 750 mm x 125 mm for testing the compressive strength, cube size of 100 mm x 100 mm x 100 mm used for testing the fire resistance and compressive strength test after being burned. Collectively, the study shows that a mixture of 2.5 % rubber tyres replacing the sand in a reinforced concrete wall panels reached 56 % from 70 % of compressive strength equivalent to 3.0 MPa from 5.4 MPa sample that no replacement with rubber tyres and acceptable. In addition, the difference percentage compressive strength of sample for 2.5 % of rubber tyre was 13 % as 9.33 MPa from 10.84 MPa before the sample is burned. Only a little difference compressive strentgth between the sample before burn. The reinforced concrete wall panels are able to achieve the standards of fire resistance of 1 hour based on ASTM Standard 119. As conclusion, the use of 2.5 % of rubber tires in reinforced concrete wall panels are capable of achieving high standards and enhance its capabilities as reusable after burning to apply in Industrilized Building System(IBS) and reduce the sudden failure of structure by knowing the pattern of cracking that will be happen on reinforced concrete wall panel.
    URI
    http://dspace.unimap.edu.my:80/xmlui/handle/123456789/40643
    Collections
    • School of Environmental Engineering (FYP) [638]

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback
     

     

    Browse

    All of UniMAP Library Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback