Show simple item record

dc.creatorBalasena, Gowry
dc.date2017
dc.date.accessioned2023-03-07T02:20:28Z
dc.date.available2023-03-07T02:20:28Z
dc.identifier.urihttp://dspace.unimap.edu.my:80/xmlui/handle/123456789/78038
dc.descriptionMaster of Science in Biomedical Electronic Engineeringen_US
dc.description.abstractIn order to reduce the physical trauma caused by breast compressions, exposure to radiations and the high price of diagnostic tests, a new cost effective magnetic induction tomography (MIT) system is proposed to identify and locate tumors among the heterogeneous breast tissues. This technique operates in a non-invasive and contactless manner with the breasts. The numerical simulation imaging system consists of 16 sensor coils with 1 coil acting as the transmitter and the rest as receivers at a single time period, leading to a total of 240 receiver readings. The receiver readings and 240 generated sensitivity matrices were then used to reconstruct the images of the breast using linear back projection (LBP) algorithm after a careful comparison has been made on the algorithm with newton one-step error reconstruction (NOSER) and truncated singular value decomposition (TSVD) algorithms. The reconstructed images were assessed in terms of three essential error metrics which are the resolution (RES), magnification (MAG), and the position error (PE). The average errors are 0.004728, 13.7793, and 45.1929 for the RES, MAG and PE metrics respectively. Nonetheless, the average error metric values for the images of tumors located deepest, at the origin (0,0), show better results in terms of PE, that is -2.5356. A strong correlation between the MIT sensor readings and the size of simulated breast tumor was also observed from the adjusted R square value which is 0.998, indicating that the data fitted are very close to the regression line. The obtained results verify that the proposed MIT design and image reconstruction algorithm provide a promising alternative for breast cancer imaging although further studies are required to validate the simulation MIT data.en_US
dc.language.isoenen_US
dc.publisherUniversiti Malaysia Perlis (UniMAP)en_US
dc.rightsUniversiti Malaysia Perlis (UniMAP)en_US
dc.subjectMagnetic inductionen_US
dc.subjectTomographyen_US
dc.subjectImage reconstructionen_US
dc.subjectBreast -- Canceren_US
dc.subjectCanceren_US
dc.titleSimulation of breast cancer imaging using magnetic induction tomographyen_US
dc.typeThesisen_US
dc.contributor.advisorShahriman, Abu Bakar, Assoc. Prof. Dr.
dc.publisher.departmentSchool of Mechatronic Engineeringen_US


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record