The effect of room temperature on the generator’s winding coils temperature
Date
2014Author
Nor Zaiazmin, Yahaya
Khairul Azwan, Ismail
Muhamad Saifuldin, Abdul Manan
Atikah, Haji Awang
Metadata
Show full item recordAbstract
Thermal modeling is a method used to formulate a temperature profile for a generator. The most common types of thermal model used by researchers are transient and steady-state model. There is insufficient of information regarding prolong usage of a generator in a confined space. The purpose of this paper is to formulate an empirical temperature model for the winding coils for the duration of 24 hours and to investigate whether a peak temperature exists. From the results, it can be concluded that there is a peak temperature detected for the winding coils in a non-controlled room temperature that occurs after 9 hours of experiment. The effect of room temperature on the winding coils temperature for no load condition is only 6.6%.