• Login
    View Item 
    •   DSpace Home
    • Final Year Project Papers & Reports
    • School of Computer and Communication Engineering (FYP)
    • View Item
    •   DSpace Home
    • Final Year Project Papers & Reports
    • School of Computer and Communication Engineering (FYP)
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Bright stretching method for image enhancement of sputum specimen

    Thumbnail
    View/Open
    Abstract,Acknowledgement.pdf (484.6Kb)
    Introduction.pdf (347.1Kb)
    Literature Review.pdf (683.0Kb)
    Methodology.pdf (663.2Kb)
    Results and Discussion.pdf (1.120Mb)
    Conclusion and Recommendation.pdf (312.9Kb)
    Refference and Appendics.pdf (664.1Kb)
    Date
    2015-06
    Author
    Fatin Nabilah, Giman
    Metadata
    Show full item record
    Abstract
    Tuberculosis is a serious disease caused by infection of germ Mycobacterium tuberculosis. Sputum specimen analysis is a common method for TB bacilli detection. The Ziehl-Neelsen stain is a special stain used to identify the TB bacilli. However, there are some factors that may degrade the quality of contrast and brightness of sputum TB slide image that a blur, too bright or too dark through many processes such as exposure and staining process. Therefore, image enhancements are necessary to improve the quality of sputum TB slide image in term of contrast and brightness. This paper proposes one method for image enhancement; bright stretching algorithm using Visual Basic software version 2010. Bright stretching produces the better enhanced sputum TB slides images when threshold value is greater than bright stretching factor. Value of bright stretching factor is 175 and value of threshold is 200, which the difference between value of bright stretching factor and threshold is 25, produced the better enhanced image in terms of contrast and brightness of Ziehl-Neelsen sputum TB image. The results show that bright stretching method is successfully improved the quality of Ziehl-Neelsen sputum TB image in terms of contrast and brightness.
    URI
    http://dspace.unimap.edu.my:80/xmlui/handle/123456789/41772
    Collections
    • School of Computer and Communication Engineering (FYP) [310]

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback
     

     

    Browse

    All of UniMAP Library Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback