Show simple item record

dc.contributor.authorAmeen, Ahmadul
dc.contributor.authorMollik, , S. A.
dc.contributor.authorMahmud, Khizir
dc.contributor.authorGhulam, Abdul Quadir, Prof. Dr.
dc.contributor.authorSeetharamu, Kankanhally N.
dc.date.accessioned2014-04-22T06:54:06Z
dc.date.available2014-04-22T06:54:06Z
dc.date.issued2006
dc.identifier.citationInternational Journal of Refrigeration, vol. 29(3), 2006, pages 495-504en_US
dc.identifier.issn0140-7007
dc.identifier.urihttp://dspace.unimap.edu.my:80/dspace/handle/123456789/33893
dc.descriptionLink to publisher's homepage at http://www.sciencedirect.com/en_US
dc.description.abstractThe present paper discusses (a) the analysis of a wire-on-tube condenser under varying operating conditions of free convection using FEM, and (b) experimental verification of the performance of two wire-on-tube condensers in a retrofitted domestic refrigerator using refrigerant R-134a. The study is motivated by the desire to investigate if the wire-on-tube condensers used in R-12 based refrigerators could be used in a modified refrigerator using R-134a refrigerant. Experiments were conducted in a climate chamber under controlled and varying ambient temperatures and mass flow rates to determine the locations where phase change occurs and the degree of subcooling achieved. In terms of initial and final phase change point locations the predicted results agree with the experimental results to within ±10%. The analysis and the experiments also lead to the information about the adequacy of the number of tubes for complete condensation of the refrigerant vapour under given operating conditions. The methodology can be used as a design tool for the design of wire-on-tube condenser of a small refrigerator as well as the suitability of specific decommissioned condensers for use in a retrofitted refrigerator. It also indicates that R-12 based refrigerators using wire-on-tube condensers retrofitted with R-134a compressor and refrigerant deserve and warrant further studies for adoption.en_US
dc.language.isoenen_US
dc.publisherElsevier Ltd.en_US
dc.subjectHousehold refrigeratoren_US
dc.subjectCondenseren_US
dc.subjectSurveyen_US
dc.subjectExperimenten_US
dc.subjectHeat transferen_US
dc.subjectFree convectionen_US
dc.subjectR-134aen_US
dc.subjectCFDen_US
dc.titleNumerical analysis and experimental investigation into the performance of a wire-on-tube condenser of a retrofitted refrigeratoren_US
dc.typeArticleen_US
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S0140700705001416
dc.identifier.urlhttp://dx.doi.org/10.1016/j.ijrefrig.2005.07.001