Now showing items 1-17 of 17

    • Application study on bubble detection in a metallic bubble column using electrical resistance tomography 

      Suzanna, Ridhuan Aw; Ruzairi, Abdul Rahim, Prof. Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Fazlul Rahman, Mohd Yunus; Naizatul Shima, Fadzil; Mohd Zikrillah, Zawahir; Mohd Fahajumi, Jumaah; Muhammad Jaysuman, Pusppanathan; Nor Muzakkir, Nor Ayob; Yasmin, Abdul Wahab; Salinda, Buyamin, Dr. (Penerbit UTM Press, 2014)
      Electrical RESISTANCE tomography (ERT) has been chosen as the field of study because of its advantages of being low COST, suitable for various kinds and sizes of pipes and vessels, having no radiation hazard, and being ...
    • Design consideration for front-end system in ultrasonic tomography 

      Nor Muzakkir, Nor Ayob; Muhammad Jaysuman, Pusppanathan; Ruzairi, Abdul Rahim, Prof. Dr. ; Mohd Hafiz, Fazalul Rahiman, Dr.; Fazlul Rahman, Mohd Yunus; Salinda, Buyamin, Dr.; Intan Maisarah, Abd Rahim; Yusri, Md. Yunos, Dr. (Penerbit UTM Press, 2013)
      The hardware development of the ultrasonic tomography comprises three main parts; the sensor unit, electronic measurement circuits combined with a data acquisition system and finally the display unit. The research done is ...
    • Development of parallel and fan-shaped beam mixed-projection optical tomography 

      Siti Zarina, Mohd. Muji, Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Mohd Hafiz, Fazalul Rahiman; Yusry, Yunus; Zulkarnay, Zakaria; Nor Muzakkir, Nor Ayub (International Frequency Sensor Association Publishing (IFSA), 2012-05)
      Parallel and fan shaped beam are two common projections that had been used widely in optical tomography system. These projections never have been merged before in the process of tomography area. In this paper, some ...
    • Edge detection algorithm for enhancement of linear back projection tomographic images 

      Muhammad Jaysuman, Pusppanathan; Mahdi Faramarzi; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr.; Fatin Aliah, Phang Abdullah, Dr.; Usman Ullah, Sheikh, Dr.; Loew,  Pei Ling, Dr.; Khairul Hamimah, Abas; Mohd Hafiz, Fazalul Rahiman, Dr.; Shafishuhaza, Sahlan (Penerbit UTM Press, 2014)
      Process tomography (PT) is a leading technique for multiphase flow measurement and flow monitoring systems in various fields. PT has the advantage of interpreting acquired measurement data and transforming it into visual ...
    • The hardware design technique for ultrasonic process tomography system 

      Mohd Hafiz, Fazalul Rahiman, Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Herlina, Abdul Rahim, Dr.; Nor Muzakkir, Nor Ayob (International Frequency Sensor Association Publishing (IFSA), 2012-06)
      This paper describes a work carried out to design and development an ultrasonic process tomography system. The hardware design technique is of interest of this paper. A number of 32-ultrasonic transducers have been ...
    • Image fusion using fuzzy logic pixel fusion for dual modality tomography system 

      Muhammad Jaysuman, Pusppanathan; Mahdi Faramarzi; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr. ; Fatin Aliah, Phang Abdullah, Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Anita, Ahmad, Dr.; Loew,  Pei Ling, Dr.; Khairul Hamimah, Abas (Penerbit UTM Press, 2014)
      Process tomography has been widely investigated and developed over time. The aim of this method is to measure the cross-sectional distribution of multiphase flow parameters based on its sensing technique. These single ...
    • Measurement of the content of water using light penetration 

      Mohd Fahajumi, Jumaah; Mohd Zikrillah, Zawahir; Fazlul Rahman, Mohd Yunus; Ruzairi, Abdul Rahim, Prof. Dr.; Nor Muzakkir, Nor Ayob; Muhammad Saiful Badri, Mansor; Naizatul Shima, Fadzil; Zulkarnay, Zakaria; Mohd Hafiz, Fazalul Rahiman, Dr.; Mohd Ramzam, Abdul Manaf (Penerbit UTM Press, 2014)
      In this paper we use an electronic component to produce light which is applied in testing soft tissue penetration. We used bio tissue, a slice of apple, and non-bio tissue, paper. The voltage could be adjusted to brighten ...
    • Modelling ultrasonic sensor for gas bubble profiles characterization of chemical column 

      Mohd Hafiz, Fazalul Rahiman, Dr.; Ruzairi, Abdul Rahim, Prof. Dr. ; Herlina, Abdul Rahim, Dr.; Nor Muzakkir, Nor Ayob; Elmy Johana, Mohamad, Dr.; Zulkarnay, Zakaria (Elsevier B.V., 2013)
      In this paper, we present a modelling and experimental work to characterize gas bubble profiles in chemical column using a pair of ultrasonic sensor. The gas bubble profiles from 2.90 mm to 7.50 mm diameter are of interest ...
    • Novel adjacent criterion method for improving ultrasonic imaging spatial resolution 

      Mohd Hafiz, Fazalul Rahiman, Dr; Ruzairi, Abdul Rahim, Prof. Dr.; Herlina, Abdul Rahim, Dr.; Nor Muzakkir, Nor Ayob (Institute of Electrical and Electronics Engineers (IEEE), 2012)
      In this letter, we present a novel approach for improving spatial resolution in ultrasonic tomography. The proposed technique modifies a Back-projection (BP) algorithm in reconstructing tomography images. We used 32-ultrasonic ...
    • Optical tomography hardware development for solid gas measurement using mixed projection 

      Siti Zarina, Mohd Muji; Chiew, Loon Goh; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr. ; Mohd Hafiz, Fazalul Rahiman, Dr.; Herlina, Abdul Rahim, Dr.; Muhammad Jaysuman, Pusppanathan; Naizatul Shima, Mohd Fadzil (Elsevier Ltd, 2013-10)
      The ability to implement fan beam projection in parallel view in an optical tomography setup is one of the novelties of this research. This design involves a sensor jig specifically designed for parallel applications that ...
    • A review of tomography system 

      Juliza, Jamaludin; Mohd Zikrillah, Zawahir; Ruzairi, Abdul Rahim, Prof. Dr. ; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Suzzana, Muhammad Ridzuan Aw; Naizatul Shima, Mohd Fadzil; Zulkarnay, Zakaria; Mohd Hafiz, Fazalul Rahiman, Dr. (Penerbit UTM Press, 2013)
      Tomography system is a method that being used to reconstruct a cross sectional image in vessel or pipeline. This method is widely used in medical and industrial fields. The aim of this paper is to provide an overview of ...
    • Simulative study of two-phase homogenous and isotropic media imaging using magnetic induction tomography 

      Zulkarnay, Zakaria; Ibrahim, Balkhis; Lee, Pick Yern; Nor Muzakkir, Nor Ayob; Mohd Hafiz, Fazalul Rahiman, Dr.; Mohd Zikrillah, Zawahirah; Ruzairi, Abdul Rahim, Prof. Dr. (Penerbit UTM Press, 2014)
      Magnetic induction tomography is a new non-invasive technology, based on eddy current discovery of electromagnetic induction by Michael Faraday. Through this technique, the passive electrical properties distribution of an ...
    • Small gas component detection using ultrasonic transmission-mode tomography system 

      Nor Muzakkir, Nor Ayob; Muhammad Jaysuman, Pusppanathan; Ruzairi, Abdul Rahim, Prof. Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Fazlul Rahman, Mohd Yunus; Zulkarnay, Zakaria; Goh, Chiew Loon; Salinda, Buyamin, Dr.; Nasarudin, Ahmad; Yusri, Md. Yunos, Dr.; Norhaliza, Abdul Wahab, Assoc. Prof. Dr. (Penerbit UTM Press, 2014)
      This paper presents the development of an ultrasonic transmission-mode tomography system for the detection of small gas components by using higher frequency ultrasonic transducers. The selection of the transducer is important ...
    • Study and Design of an Ultrasonic Flow Tomographic Front-End Multi Level Measurement System 

      Goh, Chiew Loon; Ruzairi, Abdul Rahim, Prof. Dr. ; Suzanna, Ridhuan Aw; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Mohd Hafiz, Fazalul Rahiman, Dr.; Anita, Ahmad, Dr.; Nasarudin, Ahmad; Khairul Hamimah, Abas (Penerbit UTM Press, 2014)
      With the rapid evolution of electro-acoustical technology, ultrasonic tomography has made considerable progress in industry. An ultrasonic tomography system provides non-invasive and non-intrusive flow visualisation that ...
    • Study of the effect of brightness after penetration of light from a lens 

      Mohd Fahajumi, Jumaah; Mohd Zikrillah, Zawahir; Fazlul Rahman, Mohd Yunus; Ruzairi, Abdul Rahim, Prof. Dr.; Nor Muzakkir, Nor Ayob; Muhammad Saiful Badri, Mansor; Naizatul Shima, Mohd Fadzil; Zulkarnay, Zakaria; Mohd Hafiz, Fazalul Rahiman, Dr. (Penerbit UTM Press, 2013)
      There are many types of component that are able to produce light and the light is produced based on the angle and wavelength of the lens. Light penetration depends on the type of material used. The tests are done using ...
    • Study on wireless sensor based industrial tomography systems 

      Chiew, Loon Goh; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr.; Herlina, Abdul Rahim, Dr.; Muhammad Jaysuman, Pusppanathan; Mohd Hafiz, Fazalul Rahiman, Dr.; Loew,  Pei Ling, Dr.; Zulkarnay, Zakaria (International Frequency Sensor Association Publishing (IFSA), 2013)
      Wireless sensor technologies are promising in the field of industrial tomography system, to visualize the cross-sectional images of an industrial flow process. The aim of the paper is to review the technical and scientific ...
    • Ultrasonic tomography imaging for liquid-gas flow measurement 

      Muhammad Jaysuman, Pusppanathan; Nor Muzakkir, Nor Ayob; Fazlul Rahman, Mohd Yunus; Khairul Hamimah, Abbas; Herlina, Abdul Rahim, Dr.; Loew,  Pei Ling, Dr.; Ruzairi, Abdul Rahim, Prof. Dr. ; Fatin Aliah, Phang Abdullah, Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Zulkarnay, Zakaria (International Frequency Sensor Association (IFSA), 2013)
      This research was carried out to measure two-phase liquid - gas flow regime by using a dual functionality ultrasonic transducer. Comparing to the common separated transmitter-receiver ultrasonic pairs transducer, the dual ...