Now showing items 1-9 of 9

    • Design consideration for front-end system in ultrasonic tomography 

      Nor Muzakkir, Nor Ayob; Muhammad Jaysuman, Pusppanathan; Ruzairi, Abdul Rahim, Prof. Dr. ; Mohd Hafiz, Fazalul Rahiman, Dr.; Fazlul Rahman, Mohd Yunus; Salinda, Buyamin, Dr.; Intan Maisarah, Abd Rahim; Yusri, Md. Yunos, Dr. (Penerbit UTM Press, 2013)
      The hardware development of the ultrasonic tomography comprises three main parts; the sensor unit, electronic measurement circuits combined with a data acquisition system and finally the display unit. The research done is ...
    • Gas hold-up profiles determination by means of ultrasonic transducer 

      Mohd Hafiz, Fazalul Rahiman, Dr.; Ruzairi, Abdul Rahim, Prof. Dr. ; Herlina, Abdul Rahim, Dr.; Zulkarnay, Zakaria; Muhammad Jaysuman, Pusppanathan; Goh, Chiew Loon; Nasarudin, Ahmad; Yasmin, Abdul Wahab; Fazlul Rahman, Mohd Yunus (Penerbit UTM Press, 2014)
      This paper details a work carried out to measure gas hold-up profiles in a liquid column using a pair of ultrasonic transducer. The gas hold-up profiles from 1.85 mm to 7.7 mm diameter are of interest in this investigation. ...
    • Image fusion using fuzzy logic pixel fusion for dual modality tomography system 

      Muhammad Jaysuman, Pusppanathan; Mahdi Faramarzi; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr. ; Fatin Aliah, Phang Abdullah, Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Anita, Ahmad, Dr.; Loew,  Pei Ling, Dr.; Khairul Hamimah, Abas (Penerbit UTM Press, 2014)
      Process tomography has been widely investigated and developed over time. The aim of this method is to measure the cross-sectional distribution of multiphase flow parameters based on its sensing technique. These single ...
    • Modelling ultrasonic sensor for gas bubble profiles characterization of chemical column 

      Mohd Hafiz, Fazalul Rahiman, Dr.; Ruzairi, Abdul Rahim, Prof. Dr. ; Herlina, Abdul Rahim, Dr.; Nor Muzakkir, Nor Ayob; Elmy Johana, Mohamad, Dr.; Zulkarnay, Zakaria (Elsevier B.V., 2013)
      In this paper, we present a modelling and experimental work to characterize gas bubble profiles in chemical column using a pair of ultrasonic sensor. The gas bubble profiles from 2.90 mm to 7.50 mm diameter are of interest ...
    • Optical tomography hardware development for solid gas measurement using mixed projection 

      Siti Zarina, Mohd Muji; Chiew, Loon Goh; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr. ; Mohd Hafiz, Fazalul Rahiman, Dr.; Herlina, Abdul Rahim, Dr.; Muhammad Jaysuman, Pusppanathan; Naizatul Shima, Mohd Fadzil (Elsevier Ltd, 2013-10)
      The ability to implement fan beam projection in parallel view in an optical tomography setup is one of the novelties of this research. This design involves a sensor jig specifically designed for parallel applications that ...
    • A review of the optical tomography system 

      Juliza, Jamaludin; Ruzairi, Abdul Rahim, Prof. Dr. ; Herlina, Abdul Rahim, Dr.; Naizatul Shima, Mohd Fadzil; Mohd Hafiz, Fazalul Rahiman, Dr.; Mohd Fahajumi, Jumaah; Siti Zarina, Mohd Muji, Dr.; Mohd. Amri, Md Yunus, Dr. (Penerbit UTM Press, 2014)
      Tomography is a method that has been used for image reconstruction in the medical and engineering fields. Optical tomography is one of the various methods APPLIED in tomography systems. This tomography method is widely ...
    • A review of tomography system 

      Juliza, Jamaludin; Mohd Zikrillah, Zawahir; Ruzairi, Abdul Rahim, Prof. Dr. ; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Suzzana, Muhammad Ridzuan Aw; Naizatul Shima, Mohd Fadzil; Zulkarnay, Zakaria; Mohd Hafiz, Fazalul Rahiman, Dr. (Penerbit UTM Press, 2013)
      Tomography system is a method that being used to reconstruct a cross sectional image in vessel or pipeline. This method is widely used in medical and industrial fields. The aim of this paper is to provide an overview of ...
    • Study and Design of an Ultrasonic Flow Tomographic Front-End Multi Level Measurement System 

      Goh, Chiew Loon; Ruzairi, Abdul Rahim, Prof. Dr. ; Suzanna, Ridhuan Aw; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Mohd Hafiz, Fazalul Rahiman, Dr.; Anita, Ahmad, Dr.; Nasarudin, Ahmad; Khairul Hamimah, Abas (Penerbit UTM Press, 2014)
      With the rapid evolution of electro-acoustical technology, ultrasonic tomography has made considerable progress in industry. An ultrasonic tomography system provides non-invasive and non-intrusive flow visualisation that ...
    • Ultrasonic tomography imaging for liquid-gas flow measurement 

      Muhammad Jaysuman, Pusppanathan; Nor Muzakkir, Nor Ayob; Fazlul Rahman, Mohd Yunus; Khairul Hamimah, Abbas; Herlina, Abdul Rahim, Dr.; Loew,  Pei Ling, Dr.; Ruzairi, Abdul Rahim, Prof. Dr. ; Fatin Aliah, Phang Abdullah, Dr.; Mohd Hafiz, Fazalul Rahiman, Dr.; Zulkarnay, Zakaria (International Frequency Sensor Association (IFSA), 2013)
      This research was carried out to measure two-phase liquid - gas flow regime by using a dual functionality ultrasonic transducer. Comparing to the common separated transmitter-receiver ultrasonic pairs transducer, the dual ...