A study of workers posture on napier harvest process
(Universiti Malaysia Perlis (UniMAP), 2012-06-18)
Workers in the agriculture industry are extremely exposed to the risk of musculoskeletal disorders (MSDs) either in short or long term which is directly affected to the production outputs. As initial, this paper will review ...
Computational analysis of hemodynamic effect on mismatch end-to-end reverse saphenous vein graft diameters
(Universiti Malaysia Perlis (UniMAP), 2012-06-18)
Artery reconstruction in upper extremities is rare performed compared to the incidence of reconstruction in lower extremities. Primary vascular repair was performed in many cases. An interposition vein graft or venous ...
The development of a low cost cata glove by using flexible bend sensor for resistive interfaces
(Universiti Malaysia Perlis (UniMAP), 2012-06-18)
In this paper, the development of a new low cost DataGlove system based on fingertip bending tracking techniques is presented as an alternative to expensive devices. The purpose of the research is to design a robust and ...
Development of an adaptive hand gesture database: Motion trajectories cue
(Universiti Malaysia Perlis (UniMAP), 2012-06-18)
The developments of computer technology become more fascinated especially through human-computer interaction (HCI). The visual interpretations and analysis of the human body motion are the intermediary of interaction between ...
Upper extremity vein graft monitoring device after surgery procedure: a preliminary study
(Trans Tech Publications, 2014)
In most cases, surgical vein bypass or interposition vein grafting was used in both primary management of crush-avulsion amputations and on intervention for rehabilitating the patency of occluded arteries via microvascular ...
Computational fluid dynamic analysis on microvascular vein grafting: effect of mismatched conduit diameters
(IEEE Conference Publications, 2012)
An artery disease of upper extremity is uncommon happened. The most common cause of artery disease in upper extremity is atherosclerosis. In few patients with artery disease, surgical vein bypassing or vein interposition ...
Computational analysis on upper extremity vein graft: simulation on kinked vein graft
(Elsevier Ltd., 2012)
An artery reconstruction in upper extremities is rare performed compared to the artery reconstruction in lower extremities. Primary vascular repair was performed in many cases. As to alleviate vascular occlusion, an ...
Computational fluid dynamic analysis of the effect of kink conduit in microvascular vein grafting
(IJENS Publishers, 2012)
Arterial disease of the upper extremity is an uncommon occurance, most commonly caused by atherosclerosis. In some patients with arterial disease, surgical bypass by vein grafting or vein interposition may be performed. ...
Study on bovine bone surface after atmospheric plasma treatment
(IEEE Conference Publications, 2012)
This paper studies of the effect on surface characteristics of bone surface after plasma treatment. For that purpose, the experimental procedure is designed to develop atmospheric plasma jet device. The physical processes ...
Speech analysis based on image information from lip movement
(IOP Publishing Ltd, 2013)
Deaf and hard of hearing people often have problems being able to understand and lip read other people. Usually deaf and hard of hearing people feel left out of conversation and sometimes they are actually ignored by other ...