Browsing Nashrul Fazli Mohd Nasir, Assoc. Prof. Dr. by Title
Now showing items 22-29 of 29
-
Prolonging glucose sensor's performance in In Vivo environment
(Faculty of Computer Science & Information Technology, University of Malaya, 2006)In this paper, a sol gel based needle type biosensor using 3-glycidoxypropyl dimethylethoxy silane, as silane agent was developed to improve the immobilization efficiency of glucose oxidase (GOD). The glucose sensor was ... -
Properties of Al and Pd contacts on n-type SiC membranes
(Materials Research Society, 2012-04)Membranes with dimensions up to 10 mm x 15 mm have been fabricated in epitaxial 3C-SiC/Si wafers. An array of CTLM metal contacts was deposited onto the upper surface of the n-SiC membrane. Both Al/n-SiC and Pd/n-SiC ... -
Psychological Stress Sensor
(Kementerian Pengajian Tinggi Malaysia (KPTM), 2005-09-30)Stress could be roughly described as the opposite of relaxation. This state is referred as the reaction of a human to external stimulus by a famous endocrinologist, Hans Selye in 1936. Stress signifies different things for ... -
A quantitative study of post-biopsy radiofrequency cauterization
(Springer-Verlag, 2007)Percutaneous image-guided needle biopsy is typically performed in highly vascular organs or in tumors with rich macroscopic and microscopic blood supply. The main risks related to this procedure are bleeding and implantation ... -
Specific contact resistance of ohmic contacts to n-type SiC membranes
(Materials Research Society, 2011-04)Membranes of epitaxial SiC have been used as a means of eliminating the leakage current into the Si substrate during circular transmission line model (CTLM) measurements. In the n +- 3C-SiC/ Si wafers, the Si substrate was ... -
The study of morphological structure, phase structure and molecular structure of collagen-PEO 600K blends for tissue engineering application
(Science Publications, 2006)A new material which is collagen/ poly (ethylene oxide) (PEO) blend was developed to determine its possibility as a promising material for tissue scaffold. PEO with average molecular weight of 600,000 and collagen originated ... -
Syllabus enhancement for electromagnetic course in biomedical electronics engineering at Universiti Malaysia Perlis
(Springer-Verlag., 2008-06)Biomedical engineering has evolved over the years until now virtually all engineering disciplines are engaged in “the application of engineering principles to problems of the life sciences”. Universiti Malaysia Perlis ... -
Temperature modeling of therapeutic ultrasound: a preliminary finding
(Springer-Verlag, 2007)The temperature model of therapeutic ultrasound for human tissue is important in order to design an accurate instrumental assessment and calibration of therapeutic ultrasound device. The focus of this study is to verify ...