Comparison on losses and flux distribution between two of 3 phase distribution transformer core 3000 kVA assembled with different angle of T-Joint
(Malaysia - Japan University Center (MJUC), 2007-11-15)
Thia paper describes the results of an investigation on the effect of the use of different angle of T-Joint in two models of 3 phase distribution transformer with capacity of 3000 kVA. The first model uses 3 phase distribution ...
Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
(Universiti Malaysia Perlis (UniMAP), 2008-03-10)
This paper describe the result of an investigation on the effect of different stack of core lamination in the two of 3 phase distribution transformer 1000kVA. The investigation involves the variation of power loss, building ...
Comparison on losses and flux distribution among the three of 3 phase distribution transformer 1000kVA assembled from various amount of layer of transformer core lamination
(Universiti Kuala Lumpur (UniKL), 2007-12-13)
This paper describes the results of an investigation on the effect of different amount of layer of core lamination in three of 3 phase distribution transformers 1000kVA. The investigation involves the varian of power loss, ...
Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination
(Universiti Kuala Lumpur (UniKL), 2007-12-13)
This paper describes the results of an investigarion on the effect of different amount of layers per stack of core lamination in the three of 3 phase distribution transformers 1000kVA. The investigation involves the variant ...
Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
(The Malaysian Research Group (MRG), 2007-12-06)
This paper describe the result of an investigation on the effect of different stack of core lamination in the two of 3 phase distribution transformer 1000kVA. The investigation involves the variation of power loss, building ...
Comparison between the localized power loss and flux distribution in a three phase distribution transformer 100 kva assembled from various type of T-joint geometry with Staggered Yoke
(ACTA Press, 2008-04-02)
This paper describes the result of an investigation of the variation of localized power loss and flux distribution in 3-phase transformer cores 100kVA assembled from various types of T-joint geometry. The localized power ...
Measurement of flux density distribution on 100kVA 3-Phase distribution transformer assembled with 90° T-joint and mitred lap corner joint with stagger yoke by using search coil
(Institute of Electrical and Electronics Engineers (IEEE), 2008-12-01)
This paper describes the result of measurement of flux distribution on 100kVA 3phase distribution transformer assembled with 90° T-joint and mitred lap corner joint with stagger yoke. The measurement involves the variation ...
In-plane flux distribution in 45o T-joint of 3phase transformer core with staggered yoke and limb 10mm
(ACTA Press, 2009-09-07)
This paper describes the result of measurement of inplane flux distribution on 100kVA 3phase distribution transformer assembled with 45o T-joint and mitred lap corner joint with stagger yoke and limb with overlap length ...