Now showing items 1-6 of 6

    • Advancements in Transmitters and Sensors for Biological Tissue Imaging in Magnetic Induction Tomography 

      Zulkarnay, Zakaria; Ruzairi, Abdul Rahim; Muhammad Saiful Badri, Mansor; Sazali, Yaacob; Nor Muzakkir, Nor Ayob; Siti Zarina, Mohd. Muji; Mohd Hafiz Fazalul, Rahiman; Syed Mustafa Kamal, Syed Aman (MDPI AG, 2012-05-29)
      Magnetic Induction Tomography (MIT), which is also known as Electromagnetic Tomography (EMT) or Mutual Inductance Tomography, is among the imaging modalities of interest to many researchers around the world. This noninvasive ...
    • Improving gas component detection of an ultrasonic tomography system for monitoring liquid/gas flow 

      N. M., Nor Ayob; Sazali, Yaacob, Prof. Dr.; Zulkarnay, Zakaria; Ruzairi, Abd Rahim; M. R., Manan (Institute of Electrical and Electronics Engineers (IEEE), 2010-05-21)
      The development of an ultrasonic transmission tomography system is described. The system is intended for the imaging of two component flows (such as gas/water) inside pipes of industrial processes. Transmission-mode ...
    • Magnetic induction tomography modeling in biological tissue imaging using two-port network technique 

      Muhammad Saiful Badri, Mansor; Mohd Fahajumi, Jumaah; Zulkarnay, Zakaria; Ruzairi, Abdul Rahim, Prof. Dr. ; Nor Muzakkir, Nor Ayob; Khairul Hamimah, Abbas; Siti Zarina, Mohd Muji; Sazali, Yaacob, Prof. Dr.; Herlina, Abdul Rahim, Dr.; Loew,  Pei Ling, Dr. (International Frequency Sensor Association (IFSA), 2013)
      Magnetic Induction Tomography (MIT) is a non-invasive and non-intrusive imaging technique which interested in passive electrical properties of a material that are permittivity, permeability and conductivity. MIT applies ...
    • Performance comparisons of new excitation coil design aspects in Magnetic Induction Tomography (MIT) applications 

      Zulkarnay, Zakaria; Muhamad Hafiz, Hussin; Ruzairi, Abdul Rahim; Nur Farahiyah, Mohammad; Azian Azamimi, Abdullah; Sazali, Yaacob, Prof. Dr.; Syed Mustafa Kamal, Syed Aman (Institute of Electrical and Electronics Engineers (IEEE), 2011-01-24)
      Magnetic Induction Tomography (MIT) is a contactless method interested in conductivity properties of the object. In MIT system, excitation coil plays an important role since it generate primary field which then will propagate ...
    • Review on interaction between electromagnetic field and biological tissues 

      Zulkarnay, Zakaria; Ruzairi, Abdul Rahim, Prof. Dr.; Lee, Pick Yern; Muhammad Saiful Badri, Mansor; Azian Azamimi, Abdullah; Sazali, Yaacob, Prof. Dr.; Siti Zarina, Mohd Muji (International Frequency Sensor Association (IFSA), 2012)
      The objective of this paper is to have a look on the interaction of electromagnetic field (EM) on biological tissue from the view of physiological and electrical engineering. The understanding of the phenomena in the ...
    • Simulation on using cross-correlation technique for two-phase liquid/gas flow measurement for Ultrasonic Transmission Tomography 

      Nor Muzakkir, Nor Ayob; Sazali, Yaacob, Prof. Dr.; Zulkarnay, Zakaria; Mohd Hafiz, Fazalul Rahiman; Ruzairi, Abd Rahim (Institute of Electrical and Electronics Engineers (IEEE), 2010-05-21)
      Combining Ultrasonic Transmission Tomography (UTT) with the cross-correlation flow measurement technique can provide more information on the flow than usual. A simulated dual-plane UTT system for use on laboratory and ...