Search
Now showing items 1-7 of 7
Loss prediction of induction motor using OPERA 2D software
(Universiti Malaysia Perlis (UniMAP), 2010-10-16)
The paper discusses the factors which determine the
losses of induction motor. The loss mechanisms are
described in this paper and it is related to the
performance and design characteristics of induction
motor such as ...
Comparison of flux density between different thicknesses of non oriented electrical steel material using FEM software
(Universiti Malaysia Perlis (UniMAP), 2010-10-16)
Generally, 0.35mm has better performance than 0.5mm thickness of material in terms of losses reduction and money saving potential. This paper presents the comparison of the 0.35mm and 0.5mm thickness of non oriented ...
Fabrication and investigation of copper rotor bar on 0.5HP induction Motor-A performance and economical study
(Australian Journal of Basic and Applied Sciences, 2011-05)
The paper deals with the fabrication of copper rotor bars for 0.5HP induction motor and then comparing it with the existing aluminium rotor bars. From this experiment the rotors are compared in terms of efficiency increment ...
In house construction of an induction motor rotor by using 0.35mm thickness of steel sheet for efficiency based investigation
(Trans Tech Publications, 2012)
In this paper, an in house production of a 0.5hp induction motor's rotor is investigated. This investigation considers the induction motor's efficiency and losses dissipation as an important aspect to determine the rotors ...
Performance comparison different thickness of non oriented electrical steel material using analysis and performance chart from FEM software
(Universiti Malaysia Perlis (UniMAP), 2010-10-16)
With market condition today, the economics are
such that users and engineer are looking for the best
fit for the application at the most reasonable cost in
purchasing induction motors. Generally, 0.35mm
thickness of ...
The effect of different stator slot size on the stator copper loss
(Universiti Malaysia Perlis (UniMAP), 2010-10-16)
The input power to an induction motor is in the form of three phase electric voltages and currents. The first losses encountered in the machine are I2R losses in the stator winding. The stator copper loss occurs when the ...
Effect of different size of rotor bars on induction motor efficiency
(Universiti Malaysia Perlis (UniMAP), 2010-10-16)
Efficiency is the main consideration in designing of any equipment. In an induction motor, there are many parameters that could affect the motor efficiency. One of them is the size of rotor bar, that contribute to the rotor ...