Search
Now showing items 1-8 of 8
Comparison on losses and flux distribution between two of 3 phase distribution transformer core 3000 kVA assembled with different angle of T-Joint
(Malaysia - Japan University Center (MJUC), 2007-11-15)
Thia paper describes the results of an investigation on the effect of the use of different angle of T-Joint in two models of 3 phase distribution transformer with capacity of 3000 kVA. The first model uses 3 phase distribution ...
Comparison of losses and flux distribution in 3 phase 100 kVA distribution transformers assembled from various type of T-Joint geometry
(Science Publications, 2006)
This paper describes results of an investigation of the variation of power loss, building factor, flux leakage and flux distribution in 3-phase model transformer cores assembled from various type of T-joint geometry. The ...
Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
(Universiti Malaysia Perlis (UniMAP), 2008-03-10)
This paper describe the result of an investigation on the effect of different stack of core lamination in the two of 3 phase distribution transformer 1000kVA. The investigation involves the variation of power loss, building ...
Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination
(Universiti Kuala Lumpur (UniKL), 2007-12-13)
This paper describes the results of an investigarion on the effect of different amount of layers per stack of core lamination in the three of 3 phase distribution transformers 1000kVA. The investigation involves the variant ...
Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
(The Malaysian Research Group (MRG), 2007-12-06)
This paper describe the result of an investigation on the effect of different stack of core lamination in the two of 3 phase distribution transformer 1000kVA. The investigation involves the variation of power loss, building ...
Comparison between the localized power loss and flux distribution in a three phase distribution transformer 100 kva assembled from various type of T-joint geometry with Staggered Yoke
(ACTA Press, 2008-04-02)
This paper describes the result of an investigation of the variation of localized power loss and flux distribution in 3-phase transformer cores 100kVA assembled from various types of T-joint geometry. The localized power ...
Measurement of flux density distribution on 100kVA 3-Phase distribution transformer assembled with 90° T-joint and mitred lap corner joint with stagger yoke by using search coil
(Institute of Electrical and Electronics Engineers (IEEE), 2008-12-01)
This paper describes the result of measurement of flux distribution on 100kVA 3phase distribution transformer assembled with 90° T-joint and mitred lap corner joint with stagger yoke. The measurement involves the variation ...
Comparison on losses and flux distribution between two 3-phase distribution transformers 1000kVA assembled with air gap and without air gap of transformer core lamination
(Institute of Electrical and Electronics Engineering (IEEE), 2007-12-06)
This paper describes the result of an investigation on the effect of air gap of core lamination in two 3-phase distribution transformers 1000kVA. The investigation involves the variation of power loss, building factor, the ...