Search
Now showing items 1-9 of 9
Comparison on losses and flux distribution between two of 3 phase distribution transformer core 3000 kVA assembled with different angle of T-Joint
(Malaysia - Japan University Center (MJUC), 2007-11-15)
Thia paper describes the results of an investigation on the effect of the use of different angle of T-Joint in two models of 3 phase distribution transformer with capacity of 3000 kVA. The first model uses 3 phase distribution ...
Comparison of losses and flux distribution in 3 phase 100 kVA distribution transformers assembled from various type of T-Joint geometry
(Science Publications, 2006)
This paper describes results of an investigation of the variation of power loss, building factor, flux leakage and flux distribution in 3-phase model transformer cores assembled from various type of T-joint geometry. The ...
Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
(Universiti Malaysia Perlis (UniMAP), 2008-03-10)
This paper describe the result of an investigation on the effect of different stack of core lamination in the two of 3 phase distribution transformer 1000kVA. The investigation involves the variation of power loss, building ...
Comparison on losses and flux distribution among the three of 3 phase distribution transformer 1000kVA assembled from various amount of layer of transformer core lamination
(Universiti Kuala Lumpur (UniKL), 2007-12-13)
This paper describes the results of an investigation on the effect of different amount of layer of core lamination in three of 3 phase distribution transformers 1000kVA. The investigation involves the varian of power loss, ...
Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination
(Universiti Kuala Lumpur (UniKL), 2007-12-13)
This paper describes the results of an investigarion on the effect of different amount of layers per stack of core lamination in the three of 3 phase distribution transformers 1000kVA. The investigation involves the variant ...
Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
(The Malaysian Research Group (MRG), 2007-12-06)
This paper describe the result of an investigation on the effect of different stack of core lamination in the two of 3 phase distribution transformer 1000kVA. The investigation involves the variation of power loss, building ...
Comparison on losses and flux distribution between two 3-phase distribution transformers 1000kVA assembled with air gap and without air gap of transformer core lamination
(Institute of Electrical and Electronics Engineering (IEEE), 2007-12-06)
This paper describes the result of an investigation on the effect of air gap of core lamination in two 3-phase distribution transformers 1000kVA. The investigation involves the variation of power loss, building factor, the ...
Effect of stack of transformer core lamination on losses and flux distribution in 3-phase distribution transformers 1000kVa
(Universiti Malaysia Perlis, 2008)
This paper describes the results of an investigation on the effect of different amount of layers per stack of core lamination in the three of 3-phase distribution transformers 1000kVA. The investigation involves the variation ...
Effects of Appliances to Voltage, Current, Power Factor and Harmonic Distortion
(Kolej Universiti Kejuruteraan Utara Malaysia, 2004)
Power utility always get blame if there are power interruption occurred in residential areas. Many of the residential customers are unaware, that is electrical appliance itself one of the reason that contribute to power ...