Search
Now showing items 1-10 of 17
Building factor of Grain-Oriented Silicon Iron (3% SiFe) with different thickness on 100kVA three phase distribution transformer core
(Trans Tech Publications., 2012-03)
The power loss in laminated transformer cores is always greater than the nominal loss of the electrical steel laminations, by a factor known as the building factor. This paper discussed result of an investigation towards ...
Simulation of flux distribution and loss calculation at three-phase transformer core with the mix 60o-45o T-joint
(Universiti Malaysia Perlis (UniMAP), 2010-10-16)
This paper describes the result of simulation of flux
distribution on 100kVA 3phase distribution transformer
assembled with 23o T-joint and mitred lap corner joint with
stagger yoke and limb for one lamination. The ...
Comparison on losses and flux distribution between two of 3 phase distribution transformer core 3000 kVA assembled with different angle of T-Joint
(Malaysia - Japan University Center (MJUC), 2007-11-15)
Thia paper describes the results of an investigation on the effect of the use of different angle of T-Joint in two models of 3 phase distribution transformer with capacity of 3000 kVA. The first model uses 3 phase distribution ...
Comparison of losses and flux distribution in 3 phase 100 kVA distribution transformers assembled from various type of T-Joint geometry
(Science Publications, 2006)
This paper describes results of an investigation of the variation of power loss, building factor, flux leakage and flux distribution in 3-phase model transformer cores assembled from various type of T-joint geometry. The ...
Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
(Universiti Malaysia Perlis (UniMAP), 2008-03-10)
This paper describe the result of an investigation on the effect of different stack of core lamination in the two of 3 phase distribution transformer 1000kVA. The investigation involves the variation of power loss, building ...
Comparison on losses and flux distribution among the three of 3 phase distribution transformer 1000kVA assembled from various amount of layer of transformer core lamination
(Universiti Kuala Lumpur (UniKL), 2007-12-13)
This paper describes the results of an investigation on the effect of different amount of layer of core lamination in three of 3 phase distribution transformers 1000kVA. The investigation involves the varian of power loss, ...
Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination
(Universiti Kuala Lumpur (UniKL), 2007-12-13)
This paper describes the results of an investigarion on the effect of different amount of layers per stack of core lamination in the three of 3 phase distribution transformers 1000kVA. The investigation involves the variant ...
Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
(The Malaysian Research Group (MRG), 2007-12-06)
This paper describe the result of an investigation on the effect of different stack of core lamination in the two of 3 phase distribution transformer 1000kVA. The investigation involves the variation of power loss, building ...
Evaluation of transformer magnetizing core loss
(Asian Network for Scientific Information, 2006)
Loss in transformer core is the electrical power lost in terms of heat within the core of transformer, when core is subjected to AC magnetizing force. It is composed of several types of losses such as Hysterics loss, eddy ...
Measurement of overall power loss for different three phase 100kVA transformer core material
(Institute of Electrical and Electronics Engineers (IEEE), 2011-06-06)
This paper discussed result of an investigation towards the effect of using two different Cold Rolled Grain-Oriented (CRGO) Silicon Iron material to the 100kVA three phase distribution transformer. This experiment used M4 ...