Now showing items 1-7 of 7

    • Clamping stress effect to no load noise of single phase transformer 

      Sadanadan, Purayil Govindan (Universiti Malaysia Perlis (UniMAP)School of Electrical Systems Engineering, 2011-05)
      Single phase transformer can be sources of disturbing and annoying acoustic noise. The transformer core plays a significant role in the noise generation process. The influence of the clamping stress effects on noise levels ...
    • Design and construct a three phase 5kVA, 1/0.415kV power transformer 

      Cheng, Chu Ming (Universiti Malaysia Perlis (UniMAP)School of Electrical System Engineering, 2011-04)
      The purpose of this Final Year Project is to understanding the knowledge and theoretical of three phase transformer. The three phase transformer which is step-up from 415V to 1000V with a capacity 5kVA has been designed. ...
    • Design single phase transformer 

      Chin, Poh Keong (Universiti Malaysia Perlis (UniMAP)School of Electrical System Engineering, 2011-04)
      This project has presented the design of 1 kVA rated power, 200/100 V and cable of 1.5 cross sectional area. The design of transformer coil starts with the selection of number of turns of coil and selection of cable ...
    • Design stray field transformer 

      Gunasegaran, Ramachandran (Universiti Malaysia Perlis (UniMAP)School of Electrical System Engineering, 2011-05)
      A stray field transformer is a electrical equipment that can be reduce power losses and have high efficiency. Based on knowledge of basic principle of transformer, that rated capacity of stray field transformer is design ...
    • Development of series passive filter to reduce harmonic on single phase transformer 

      Lim, Yun Chuan (Universiti Malaysia Perlis (UniMAP)Faculty of Engineering Technology, 2015-12)
      The project is about development of series passive filter where it is used to reduce harmonic on single phase transformer. The literature review was first made to obtain the related information. Then the software ...
    • Development of shunt passive filter to reduce harmonic on single phase 1.5 kVA isolation tranformer 

      Khaw, Kai Liang (Universiti Malaysia Perlis (UniMAP)Faculty of Engineering Technology, 2015-11-20)
      This project is presents a method of using shunt passive filter for harmonic on isolation transformer. Harmonic in power system is defined as current or voltage which defined as multiple integer of system frequency or ...
    • Investigation the effect of flux density on three phase 100KVA transformer core using M4 3% silicon iron material 

      Mohamad Room, Puad (Universiti Malaysia Perlis (UniMAP)School of Electrical System Engineering, 2011-04)
      The efficient operation of power transformer cores depends to a large extent on the design of the joints between their limbs and yokes. Transformer are widely used in many sector such as industrial sector and commercial ...