dc.contributor.author | Saad Omar, Alsharif | |
dc.contributor.author | Zainal Arifin, Mohd Ishak | |
dc.contributor.author | Azlan, Ariffin | |
dc.date.accessioned | 2010-11-01T08:09:51Z | |
dc.date.available | 2010-11-01T08:09:51Z | |
dc.date.issued | 2010-06-09 | |
dc.identifier.citation | p.230-233 | en_US |
dc.identifier.isbn | 978-967-5760-02-0 | |
dc.identifier.uri | http://dspace.unimap.edu.my/123456789/10152 | |
dc.description | International Conference on X-Rays and Related Techniques in Research and Industry (ICXRI 2010) jointly organized by Universiti Malaysia Perlis (UniMAP) and X-Ray Application Malaysia Society (XAPP), 9th - 10th June 2010 at Aseania Resort Langkawi, Malaysia. | en_US |
dc.description.abstract | The aim of this study was to
investigate the influence of light emitting
diode (LED) laser with different irradiation
time on the mechanical properties of
conventional dental composite restoration.
Experimental composites were prepared from
rigid aromatic bisphenol A diglycidyl
dimethacrylate (Bis-GMA) as base monomer,
triethyleneglycoldim- ethacrylate
(TEGDMA) as diluent monomer at the ratio
(wt/wt) 60/40, 3-methacryloxypropyltrimethoxy
silane (MPS) and
hydroxyapatite (HA) as filler. The initiation
system was based on the pair
camphorquinone (CQ)/N, N dimet- hyl amino
ethyl methacrylate (DMAEMA). The
rectangular specimens (25 mm × 5 mm × 2.5
mm) were moulded in a stainless steel mold
according to ISO standard 13586:2000. And
the polymerization times were varied from 20
- 80 sec. The experimental results showed the
best polymerization times (fracture toughness
test) was used 60 seconds. Dental composite
formulated with Bis-GMA: TEGMA and HA
as filler presented the best compromise
between different irradiation time. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Universiti Malaysia Perlis | en_US |
dc.relation.ispartofseries | Proceedings of the International Conference on X-Rays & Related Techniques in Research & Industry (ICXRI) 2010 | en_US |
dc.subject | Dental composite | en_US |
dc.subject | Light curing unit | en_US |
dc.subject | Bis-GMA | en_US |
dc.subject | TEGDMA | en_US |
dc.subject | Mechanical properties | en_US |
dc.subject | Light emitting diode (LED) | en_US |
dc.subject | International Conference on X-Rays & Related Techniques in Research & Industry (ICXRI) | en_US |
dc.title | Effect of different irradiation time on the mechanical properties of conventional dental composite restoration by LED laser | en_US |
dc.type | Working Paper | en_US |
dc.publisher.department | School of Materials Engineering & School of Environmental Engineering | en_US |
dc.contributor.url | saadelsharif@yahoo.com | en_US |