Show simple item record

dc.contributor.authorSaad Omar, Alsharif
dc.contributor.authorZainal Arifin, Mohd Ishak
dc.contributor.authorAzlan, Ariffin
dc.date.accessioned2010-11-01T08:09:51Z
dc.date.available2010-11-01T08:09:51Z
dc.date.issued2010-06-09
dc.identifier.citationp.230-233en_US
dc.identifier.isbn978-967-5760-02-0
dc.identifier.urihttp://dspace.unimap.edu.my/123456789/10152
dc.descriptionInternational Conference on X-Rays and Related Techniques in Research and Industry (ICXRI 2010) jointly organized by Universiti Malaysia Perlis (UniMAP) and X-Ray Application Malaysia Society (XAPP), 9th - 10th June 2010 at Aseania Resort Langkawi, Malaysia.en_US
dc.description.abstractThe aim of this study was to investigate the influence of light emitting diode (LED) laser with different irradiation time on the mechanical properties of conventional dental composite restoration. Experimental composites were prepared from rigid aromatic bisphenol A diglycidyl dimethacrylate (Bis-GMA) as base monomer, triethyleneglycoldim- ethacrylate (TEGDMA) as diluent monomer at the ratio (wt/wt) 60/40, 3-methacryloxypropyltrimethoxy silane (MPS) and hydroxyapatite (HA) as filler. The initiation system was based on the pair camphorquinone (CQ)/N, N dimet- hyl amino ethyl methacrylate (DMAEMA). The rectangular specimens (25 mm × 5 mm × 2.5 mm) were moulded in a stainless steel mold according to ISO standard 13586:2000. And the polymerization times were varied from 20 - 80 sec. The experimental results showed the best polymerization times (fracture toughness test) was used 60 seconds. Dental composite formulated with Bis-GMA: TEGMA and HA as filler presented the best compromise between different irradiation time.en_US
dc.language.isoenen_US
dc.publisherUniversiti Malaysia Perlisen_US
dc.relation.ispartofseriesProceedings of the International Conference on X-Rays & Related Techniques in Research & Industry (ICXRI) 2010en_US
dc.subjectDental compositeen_US
dc.subjectLight curing uniten_US
dc.subjectBis-GMAen_US
dc.subjectTEGDMAen_US
dc.subjectMechanical propertiesen_US
dc.subjectLight emitting diode (LED)en_US
dc.subjectInternational Conference on X-Rays & Related Techniques in Research & Industry (ICXRI)en_US
dc.titleEffect of different irradiation time on the mechanical properties of conventional dental composite restoration by LED laseren_US
dc.typeWorking Paperen_US
dc.publisher.departmentSchool of Materials Engineering & School of Environmental Engineeringen_US