Now showing items 1-7 of 7

    • Bidirectional flow micropump based on dynamic rectification 

      Pei, Song Chee; Ruzairi, Abdul Rahim, Prof. Dr. ; Rashidah @ Siti Saedah, Arsat, Dr.; Uda, Hashim, Prof. Dr.; Loew,  Pei Ling, Dr. (Elsevier B.V., 2013)
      This paper proposes a new bidirectional pumping principle based on a dynamic rectification mechanism. The pump is composed of a moveable actuation platform and a gourd-shaped chamber, whose role is to behave as both a ...
    • Disposable polymeric electromagnetic actuated micropump 

      Chee, Pei Song; Rashidah, Arsat, Dr.; Uda, Hashim, Prof. Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Leow, Pei Ling (American Scientific Publishers, 2012-06)
      Abstract A polymer based disposable micropump was designed and evaluated for drug release and control mechanism. The micropump is constructed via hot embossing replication technique with poly(methylmethacrylate) as body ...
    • Micropump pattern replication using Printed Circuit Board (PCB) technology 

      Pei, Song Chee; Rashidah @ Siti Saedah, Arsat, Dr.; Uda, Hashim, Prof. Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Loew, Pei Ling, Dr. (Taylor and Francis Group, LLC., 2013-06-01)
      This article shows a low-cost rapid hot embossing poly (methylmeth acrylate) (PMMA)-based micropump replication with printed circuit board (PCB) mold. PCB material offers advantages of low cost, rigid, and rapid thermal ...
    • Modular architecture of a non-contact pinch actuation micropump 

      Chee, Pei Song; Rashidah, Arsat. Dr.; Tijjani Adam, Shuwa; Uda, Hashim, Prof. Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Leow, Pei Ling (MDPI, Basel, Switzerland., 2012-09)
      This paper demonstrates a modular architecture of a non-contact actuation micropump setup. Rapid hot embossing prototyping was employed in micropump fabrication by using printed circuit board (PCB) as a mold material in ...
    • Novel in-house fabrication of nano lab-on-chip devices 

      Tijjani Adam, Shuwa; Uda, Hashim, Prof. Dr.; Dhahi, Th Sabar; Leow, Pei Ling; Chee, Pei Song (Bentham Science Publishers, 2013)
      20nm SiNWs transducers have been fabricated by means of simple in-house fabrication method. A low cost, simple top-down approach has been successfully used for the fabrication of very sensitive SiNWs. The fabrication was ...
    • Polysilicon nanowire fabrication as a transducer for fast reaction assays in nano lab-on-chip domain 

      Tijjani Adam, Shuwa; Uda, Hashim, Prof. Dr.; Dhahi, Th Sabar; Foo, Kai Loong; Leow, Pei Ling; Chee, Pei Song (American Scientific Publishers, 2013-02)
      The difficulty with the treatment of cancer is caused by lack of ability to detect the tumor associated with the disease at the early stage. Often, cancer is detected in its later stages, when it has compromised the function ...
    • Selection of optimal parameters in fabrication of poly (dimethylsiloxane) microfluidics using taguchi method 

      Tijjani Adam, Shuwa; Uda, Hashim, Prof. Dr.; Leow, Pei Ling; Foo, Kai Loong; Chee, Pei Song (American Scientific Publishers, 2013-01)
      The excellent performance and achievements by the microfluidics systems at fluid flow manipulation in the recent years have ignited the passion and interest of many researchers around the world, Since a microfluidic is ...