Please use this identifier to cite or link to this item: http://dspace.unimap.edu.my:80/xmlui/handle/123456789/80233
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChew, Thum Peng-
dc.contributor.authorXian, Sean Lee Xi-
dc.date.accessioned2024-03-04T07:29:51Z-
dc.date.available2024-03-04T07:29:51Z-
dc.date.issued2021-
dc.identifier.citationThe Journal of the Institution of Engineers, Malaysia, vol.82 (2), 2021, pages 12-17en_US
dc.identifier.issn0126-513x-
dc.identifier.urihttp://dspace.unimap.edu.my:80/xmlui/handle/123456789/80233-
dc.descriptionLink to publisher’s homepages at https://www.myiem.org.my/en_US
dc.description.abstractMany lightning risk analyses avoided considering the role of the PV Module’s aluminium frame as a natural lightning air termination system or if such a role is considered, assumed that the ‘thin’ aluminium frame, would not be damaged from metal melting and evaporation at the point of lightning stroke attachment. Although the IEC 62305 is not lacking in guidance on the use of thin metal sheets as air terminations, this aspect is not considered in PV farm design. To ensure correct inputs into the risk assessment calculation, the evaluation of interception and sizing efficiencies and the damage probabilities of the natural components have to be addressed. A comparative analysis is done between two types of air terminations; the PV-frame LPS and the finial-added LPS. The result indicates that for solar PV farms exceeding a certain size and operating in high ground flash density regions like Malaysia, the finial air termination may out-perform the PV-frame LPS.en_US
dc.language.isoenen_US
dc.publisherThe Institution of Engineers, Malaysia (IEM)en_US
dc.subject.otherLightning protection systemen_US
dc.subject.otherInterception efficiencyen_US
dc.subject.otherHot-spot punctureen_US
dc.subject.otherSizing efficiencyen_US
dc.subject.otherPV module damage rateen_US
dc.subject.otherPV module replacement rateen_US
dc.titleThe impact of direct lightning strike damages on PV modules in a large Malaysian PV farmen_US
dc.typeArticleen_US
dc.identifier.urlhttps://www.myiem.org.my/-
dc.contributor.urlthumpc@gmail.comen_US
Appears in Collections:IEM Journal

Files in This Item:
File Description SizeFormat 
The impact of direct lightning strike damages on PV modules in a large Malaysian PV farm.pdfMain article716.34 kBAdobe PDFView/Open


Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.