dc.descriptionOrganized by Kolej Universiti Kejuruteraan Utara Malaysia (KUKUM), 18th - 19th May 2005 at Putra Palace Hotel, Kangar.en_US
dc.description.abstractThe present paper describes the design,simulation,fabrication and testing of a McMurray bridge inverter circuit for conversion of dc power to ac power to be used for emergency loads from a solar panel. The solar energy can be converted directly to electrical energy by using photovoltaic modules. Photovoltaic array can produce a direct d.c. and can be stored in a battery. The d.c. is converted to a.c. by using single phase McMurray Bridge Inverter with PWM firing control. It consists of three parts which are firing circuit, McMurray bridge inverter circuit and the snubber circuit. The circuit is designed for output of 75W and 12Vand simulated by OrCAD Release 9.1. It is fabricated and tested in the laboratory. The design is presented and test waveforms are shown in the results.en_US
dc.language.isoenen_US
dc.publisherKolej Universiti Kejuruteraan Utara Malaysiaen_US
dc.relation.ispartofseriesProceedings of the 1st National Conference on Electronic Designen_US
dc.subjectInverteren_US
dc.subjectInverter circuit -- Design and constructionen_US
dc.subjectSolar energyen_US
dc.subjectThyristor inverter circuiten_US
dc.subjectEmergency loadsen_US
dc.subjectRenewable energy sourcesen_US
dc.subjectElectric circuitsen_US
dc.titleDesign and testing of McMurray Inverter for Emergency Loadsen_US
dc.typeWorking Paperen_US