Please use this identifier to cite or link to this item: http://dspace.unimap.edu.my:80/xmlui/handle/123456789/68803
Title: The effect of condensate water on the performance of automotive air conditioning system under difference evaporator air inlet temperature
Authors: Mohamad Firdaus, Sukri
Rusmiati, Lokman
Asjufri, Muhajir
Faizil, Wasbari
Amir Abdullah, Muhamad Damanhur
Kasni, Sumeru
mohdfirdaus@utem.edu.my
Keywords: Vapour compression refrigeration cycle
Air conditioning system
Condensate water
Sub-cooling method
COP improvement
Issue Date: May-2020
Publisher: Universiti Malaysia Perlis (UniMAP)
Citation: International Journal of Nanoelectronics and Materials, vol.13(Special Issue), 2020, pages 85-94
Series/Report no.: International Symposium on Science, Technology and Engineering (ISSTE 2019);
Abstract: This paper experimentally investigates the effect of condensate water on the performance of automotive air conditioning (AAC) system under difference evaporator air inlet temperature. An experimental test rig was fabricated using the actual component of AAC system used for Proton Wira passenger car. During experimental work, the volume flow rate of condensate water was manipulated at 0, 140 and 340 ml/min. The evaporator air inlet temperature was also varied at 28, 32 and 36°C. The other parameters of compressor speed, condensate water temperature and condenser air inlet temperature were kept constant at 1550 rpm, 29 ± 1°C and 32 ± 1°C, respectively. The study showed that the coefficient of performance (COP) of the AAC system increases when the volume flow rate of condensate water increased from 0 to 140 ml/min. It was due to a dominant decrease in compressor work, as compared to the drop in cooling capacity. In addition, the highest increment in COP occurred at evaporator air inlet temperature of 36°C (9.8%), followed by evaporator air inlet temperature of 28°C (2.8%) and 32°C (0.4%). The highest COP is 3.66, occurred at evaporator air inlet temperature of 32°C and volume flow rate of condensate water of around 140 ml/min.
Description: Link to publisher's homepage at http://ijneam.unimap.edu.my
URI: http://dspace.unimap.edu.my:80/xmlui/handle/123456789/68803
ISSN: 1985-5761 (Printed)
1997-4434 (Online)
Appears in Collections:International Journal of Nanoelectronics and Materials (IJNeaM)

Files in This Item:
File Description SizeFormat 
The Effect of Condensate Water on the Performance.pdfMain article1.09 MBAdobe PDFView/Open


Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.