dc.description.abstractEC 2 standard and EC 8 standard as a parameter in determined the characteristic of fundamental period. From the research, the analyses were conducted based on the physical properties, and strength properties. The research is done in order to compare the properties of the building structure design under EC 2 standard and under EC 8 standard in determined the characteristic of fundamental period. Three types of frame were chosen. The frames were label as Regular Frame, Irregular Frame with Transfer Beam, and Irregular Frame with Setback. To achieve the research, all the analysis will be conducted either design by manual calculation or computer added design (CAD). SAP 2000 were used for the whole process of analysis during the research been conducted. As a result, either less physical properties in term of size, area, and amount of the reinforcement bars or less strength properties such as of yield, displacement, tensile resistance, inelastic behavior and stiffness based on structure design under EC 2 standard, produced the higher value of fundamental period from structure design under EC 8 standard. In terms of load distribution, the bigger value for bending moments of structure resulting the higher value of fundamental period. As an additional conclusion, the lesser value of the fundamental period value, the more safe for the occupants. Besides that, the cost of constructing the building was high based on the physical properties. Refer to this statement, structure design under EC 8 standards were not practical to construct in Malaysia.en_US
dc.language.isoenen_US
dc.publisherUniversiti Malaysia Perlis (UniMAP)en_US
dc.subjectReinforcement Concrete (RC)en_US
dc.subjectRC buildingen_US
dc.subjectFundamental perioden_US
dc.subjectBuilding structureen_US
dc.titleFundamental periods for medium-rise Reinforcement Concrete (RC) buildingsen_US
dc.typeLearning Objecten_US
dc.contributor.advisorMohd Zulham Affandi Mohd Zahiden_US
dc.publisher.departmentSchool of Environmental Engineeringen_US
Appears in Collections:School of Environmental Engineering (FYP)

Files in This Item:
File Description SizeFormat 
Abstract, Acknowledgement.pdf789.86 kBAdobe PDFView/Open
Introduction.pdf686.38 kBAdobe PDFView/Open
Literature Review.pdf1.01 MBAdobe PDFView/Open
Methodology.pdf1.07 MBAdobe PDFView/Open
Results and discussion.pdf2.1 MBAdobe PDFView/Open
Conclusion.pdf682.6 kBAdobe PDFView/Open
Reference and appendix.pdf3.1 MBAdobe PDFView/Open


Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.