Please use this identifier to cite or link to this item:
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/39286
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Nazrul Amir, Rejab | - |
dc.date.accessioned | 2015-03-24T03:31:23Z | - |
dc.date.available | 2015-03-24T03:31:23Z | - |
dc.date.issued | 2013-06 | - |
dc.identifier.uri | http://dspace.unimap.edu.my:80/xmlui/handle/123456789/39286 | - |
dc.description | Access is limited to UniMAP community. | en_US |
dc.description.abstract | EC 2 standard and EC 8 standard as a parameter in determined the characteristic of fundamental period. From the research, the analyses were conducted based on the physical properties, and strength properties. The research is done in order to compare the properties of the building structure design under EC 2 standard and under EC 8 standard in determined the characteristic of fundamental period. Three types of frame were chosen. The frames were label as Regular Frame, Irregular Frame with Transfer Beam, and Irregular Frame with Setback. To achieve the research, all the analysis will be conducted either design by manual calculation or computer added design (CAD). SAP 2000 were used for the whole process of analysis during the research been conducted. As a result, either less physical properties in term of size, area, and amount of the reinforcement bars or less strength properties such as of yield, displacement, tensile resistance, inelastic behavior and stiffness based on structure design under EC 2 standard, produced the higher value of fundamental period from structure design under EC 8 standard. In terms of load distribution, the bigger value for bending moments of structure resulting the higher value of fundamental period. As an additional conclusion, the lesser value of the fundamental period value, the more safe for the occupants. Besides that, the cost of constructing the building was high based on the physical properties. Refer to this statement, structure design under EC 8 standards were not practical to construct in Malaysia. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Universiti Malaysia Perlis (UniMAP) | en_US |
dc.subject | Reinforcement Concrete (RC) | en_US |
dc.subject | RC building | en_US |
dc.subject | Fundamental period | en_US |
dc.subject | Building structure | en_US |
dc.title | Fundamental periods for medium-rise Reinforcement Concrete (RC) buildings | en_US |
dc.type | Learning Object | en_US |
dc.contributor.advisor | Mohd Zulham Affandi Mohd Zahid | en_US |
dc.publisher.department | School of Environmental Engineering | en_US |
Appears in Collections: | School of Environmental Engineering (FYP) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Abstract, Acknowledgement.pdf | 789.86 kB | Adobe PDF | View/Open | |
Introduction.pdf | 686.38 kB | Adobe PDF | View/Open | |
Literature Review.pdf | 1.01 MB | Adobe PDF | View/Open | |
Methodology.pdf | 1.07 MB | Adobe PDF | View/Open | |
Results and discussion.pdf | 2.1 MB | Adobe PDF | View/Open | |
Conclusion.pdf | 682.6 kB | Adobe PDF | View/Open | |
Reference and appendix.pdf | 3.1 MB | Adobe PDF | View/Open |
Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.