Please use this identifier to cite or link to this item: http://dspace.unimap.edu.my:80/xmlui/handle/123456789/34808
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAzlan, Che Azlan-
dc.contributor.authorNashrul Fazli, Mohd Nasir, Dr.-
dc.contributor.authorNahrizul Adib, Kadri-
dc.contributor.authorAhmad Saifizul, Abdullah, Dr.-
dc.contributor.authorNg, Kwan Hoong, Prof. Dr.-
dc.date.accessioned2014-05-28T02:55:14Z-
dc.date.available2014-05-28T02:55:14Z-
dc.date.issued2007-
dc.identifier.citationp. 232-235en_US
dc.identifier.isbn978-3-540-68017-8 (Online)-
dc.identifier.isbn978-3-540-68016-1 (Print)-
dc.identifier.issn1680-0737-
dc.identifier.urihttp://link.springer.com/chapter/10.1007%2F978-3-540-68017-8_61-
dc.identifier.urihttp://dspace.unimap.edu.my:80/dspace/handle/123456789/34808-
dc.descriptionProceeding of The 3rd Kuala Lumpur International Conference on Biomedical Engineering 2006 at Kuala Lumpur, Malaysia on 11 December 2006 until 14 December 2006. Link to publisher's homepage at http://ezproxy.unimap.edu.my:2259/en_US
dc.description.abstractPercutaneous image-guided needle biopsy is typically performed in highly vascular organs or in tumors with rich macroscopic and microscopic blood supply. The main risks related to this procedure are bleeding and implantation of tumor cells in the needle tract. From numerous conducted studies, it was found that heating the needle tract using a radiofrequency (RF) ablation system has a potential to minimize these effects. However, this solution requires the use of specially designed RF needles which would make the procedure relatively expensive and complicated. Thus, in order to solve this problem, we propose a simple solution by using readily available biopsy needles connected to an RF generator. In order to do so, we have designed and developed an adapter to interface between these two devices. A bovine liver has been used as a sample tissue for the experimental procedure. The delivery of the RF was varied by varying the values for delivered power, power delivery duration, and insertion depth. The results showed that the size of the coagulation necrosis region is affected by all of the parameters tested. In general, the size of the region is enlarged with higher delivery of RF power, longer duration of power delivery, and shallower needle insertion.en_US
dc.language.isoenen_US
dc.publisherSpringer-Verlagen_US
dc.relation.ispartofseriesInternational Federation for Medical and Biological Engineering (IFMBE) Proceedings;-
dc.subjectRF ablationen_US
dc.subjectBiopsy needle interfaceen_US
dc.titleA quantitative study of post-biopsy radiofrequency cauterizationen_US
dc.typeWorking Paperen_US
dc.identifier.url10.1007/978-3-540-68017-8_61-
dc.contributor.urlazlanbme@um.edu.myen_US
dc.contributor.urlnashrul@unimap.edu.myen_US
dc.contributor.urlnahrizuladib@um.edu.myen_US
dc.contributor.urlsaifizul@um.edu.myen_US
dc.contributor.urlngkh@um.edu.myen_US
Appears in Collections:Nashrul Fazli Mohd Nasir, Assoc. Prof. Dr.

Files in This Item:
File Description SizeFormat 
A quantitative study of post-biopsy radiofrequency cauterization-abstract.pdf57.08 kBAdobe PDFView/Open


Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.