Title: | Study of dual open ended coaxial sensor system for calculation of phase using two magnitudes |
Authors: | Lee, Kim Yee Chung, Boon Kuan You, Kok Yeow Ee Meng, Cheng, Dr. Zulkifly, Abbas kylee@utar.edu.my bkchung@utar.edu.my kyyou@fke.utm.my emcheng@unimap.edu.my za@science.upm.edu.my |
Keywords: | Dual open ended coaxial sensor Modified capacitance model Phase determination Reflection coefficient |
Issue Date: | 2014 |
Publisher: | IEEE Conference Publications |
Citation: | IEEE Sensors Journal, vol. 14(1), 2014, pages 129-134 |
Abstract: | A dual open ended coaxial sensor system to determine complex permittivity was studied in detail. This paper focuses on determination of a reflection coefficient phase from two magnitudes using modified capacitance model from 300 kHz to 8 GHz. The phase information can then be used for calculation of the sample's complex permittivity. Factors such as range and limitation of the model, sample's permittivity, operating frequency, and size of sensor were investigated. Sensitivity of calculated phase with respect to small changes in measured magnitude was carried out. |
Description: | Link to publisher's homepage at http://ieeexplore.ieee.org/ |
URI: | http://dspace.unimap.edu.my:80/dspace/handle/123456789/34103 |
ISSN: | 1530-437X |
Appears in Collections: | Cheng Ee Meng, Dr. |