Please use this identifier to cite or link to this item:
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/33868
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Quadir, Abdul Quadir, Prof. Dr. | - |
dc.contributor.author | Jarallah, Saqab S. | - |
dc.contributor.author | Ahmed, Naveed J Salman | - |
dc.contributor.author | Badruddin, I. A. | - |
dc.date.accessioned | 2014-04-21T03:06:31Z | - |
dc.date.available | 2014-04-21T03:06:31Z | - |
dc.date.issued | 2013 | - |
dc.identifier.citation | International Journal of Heat and Mass Transfer, vol. 62(1), 2013, pages 562-566 | en_US |
dc.identifier.issn | 0017-9310 | - |
dc.identifier.uri | http://dspace.unimap.edu.my:80/dspace/handle/123456789/33868 | - |
dc.description | Link to publisher's homepage at http://www.sciencedirect.com/ | en_US |
dc.description.abstract | The performance of a triple concentric pipe heat exchanger is studied experimentally under steady state conditions for two different flow arrangements, called N-H-C and C-H-N, and for insulated as well as non-insulated conditions of the heat exchanger. The three fluids being considered are hot water, cold water and the normal tap water. Under N-H-C arrangement, normal water flows in the innermost pipe, hot water flows in the inner annulus, and the cold water flows in the outer annulus. All fluids flow parallel to each other. Cold and normal water are interchanged in the C-H-N arrangement keeping hot water flow unchanged. The results are presented in the form of the temperature variations of the three fluids along the length of the heat exchanger for their different flow rates. It is found that the temperature variation along the length of pipe differs substantially for the two arrangements. Temperature of cold water increases rapidly in the non-insulated condition of N-H-C arrangement. Cross over points are found in N-H-C arrangement for higher volume flow rates of the three fluids. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Ltd. | en_US |
dc.subject | Triple concentric pipe heat exchanger | en_US |
dc.subject | Experimental analysis | en_US |
dc.subject | Cross over point | en_US |
dc.title | Experimental investigation of the performance of a triple concentric pipe heat exchanger | en_US |
dc.type | Article | en_US |
dc.identifier.url | http://dx.doi.org/10.1016/j.ijheatmasstransfer.2013.03.033 | - |
dc.identifier.url | http://www.sciencedirect.com/science/article/pii/S0017931013002408 | - |
dc.contributor.url | gaquadir@unimap.edu.my | en_US |
Appears in Collections: | Ghulam Abdul Quadir, Prof. Dr. |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Experimental investigation of the performance of a triple concentric pipe heat exchanger.pdf | 119.2 kB | Adobe PDF | View/Open |
Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.