Please use this identifier to cite or link to this item: http://dspace.unimap.edu.my:80/xmlui/handle/123456789/33808
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAnas, Mohd Noor
dc.contributor.authorP. K, Lim
dc.date.accessioned2014-04-18T07:25:25Z
dc.date.available2014-04-18T07:25:25Z
dc.date.issued2013
dc.identifier.citationp. 1 – 5en_US
dc.identifier.isbn978-1-4799-0842-4
dc.identifier.urihttp://dspace.unimap.edu.my:80/dspace/handle/123456789/33808
dc.identifier.urihttp://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6717953&tag=1
dc.descriptionProceedings of 2013 IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA 2013) at Kuala Lumpur; Malaysia on 26 November 2013 through 27 November 2013.en_US
dc.description.abstractDiabetes is already the world’s most costly epidemic. Current glucose monitoring are invasive, which requires painful procedures and not reliable for long term usage. Impedance of human skin provides details about physiological structure and chemical composition of the skin and underneath tissues. Glucose concentration will affect the dielectric properties of cellular membranes, and therefore, changing the impedance of the blood. This paper describes a non-invasive measurement continuous glucose monitoring system based on bioelectrical impedance. In this project, an alternative current constant current source with a frequency of 50 kHz and peak-to-peak of 1mA is developed and injected to the finger tip through the developed tetra-polar electrode. The voltage drop across the finger will be measured and also used to determine the variation on glucose concentration. The developed prototype device will help to manage the painful procedures, cost-effective and reduce the infection rate as compared to the conventional invasive technique. Preliminary results show that 80% of measurement accuracy of the developed system measured non-invasively blood glucose by means of bioelectrical impedance.en_US
dc.language.isoenen_US
dc.publisherIEEE Conference Publicationsen_US
dc.subjectBlood-glucoseen_US
dc.subjectBioelectrical impedanceen_US
dc.subjectConstant current sourceen_US
dc.subjectNon-Invasive measurementen_US
dc.titleDevelopment of non-invasive blood-glucose measurement system A bio-impedance approachen_US
dc.typeArticleen_US
dc.identifier.urlhttp://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6717953&tag=1
dc.identifier.url10.1109/ICSIMA.2013.6717953
dc.contributor.urlanasnoor@unimap.edu.myen_US
Appears in Collections:Anas Mohd Noor



Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.