Please use this identifier to cite or link to this item: http://dspace.unimap.edu.my:80/xmlui/handle/123456789/33333
Title: Effects of anthropometric variables and electrode placement on the SEMG activity of the biceps brachii muscle during submaximal isometric contraction in arm wrestling
Authors: Nizam Uddin, Ahamed
Sundaraj, Kenneth, Assoc. Prof. Dr.
R. Badlishah, Ahmad, Prof. Dr.
Matiur, Rahman
Md. Asraf, Ali
Md. Anamul, Islam
ahamed1557@hotmail.com
kenneth@unimap.edu.my
badli@unimap.edu.my
Keywords: Anthropometric
Arm wrestling
Biceps brachii
Electrode
Electromyography
Isometric contraction
Issue Date: 2013
Publisher: Walter de Gruyter
Citation: Biomedizinische Technik/Biomedical Engineering, vol. 58(5), 2013, pages 475-488
Abstract: Surface electromyography (SEMG) has been widely used to analyze the biceps brachii (BB) muscle during voluntary contraction, and the effect of the interelectrode distance has been studied. However, the effect of anthropometric variations and the placement of electrodes on the BB activity during arm wrestling (i.e., during isometric contraction at a submaximal intensity) has seldom been investigated. In this study, the BB strength throughout this type of static contraction was evaluated. The SEMG signals were recorded from three locations on the BB: the muscle belly (M), near proximal (P), and distal tendon (L) regions. Twenty subjects who participated in the experiment were divided into five groups (A, B, C, D, and E). The average SEMG, root mean square, and variability of the signal were calculated using the coefficient of variance. The results indicated that the M region was more active and exhibited increased signal consistency (10.91%) compared with the other two regions (P: 24.47% and L: 19.13%). Significant differences were observed between the L and P regions and between the M and P regions (p<0.05); however, there were no differences between the M and L regions (p>0.05). The increase in the SEMG value in groups B and C was significant (p<0.05), whereas groups A, D, and E did not exhibit a significant increase (p>0.05). In addition, muscle size was the strongest predictor of strength compared with body weight and height. The results suggest that the M region displays considerable SEMG effects and signal reliability. Furthermore, the SEMG measurements were found to correlate strongly with the strength of the contractions and the muscle size, and not with weight and height.
Description: Link to publisher's homepage at http://www.degruyter.com/
URI: http://dspace.unimap.edu.my:80/dspace/handle/123456789/33333
ISSN: 1862-278X (Online)
0013-5585 (Print)
Appears in Collections:Kenneth Sundaraj, Assoc. Prof. Dr.



Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.