Please use this identifier to cite or link to this item:
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/27715
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Abdul Hafiz Syafiq, Rozali | - |
dc.date.accessioned | 2013-08-27T04:20:35Z | - |
dc.date.available | 2013-08-27T04:20:35Z | - |
dc.date.issued | 2011-04 | - |
dc.identifier.uri | http://dspace.unimap.edu.my/123456789/27715 | - |
dc.description | Access is limited to UniMAP community. | en_US |
dc.description.abstract | Soil resistivity data is the key factor in designing a grounding system for a specific performance objective like a climate factor. All soil conducts electrical current, with some soil having good electrical conductivity while the majority has poor electrical conductivity. The resistivity of soil varies widely throughout the world and change dramatically within small areas. Soil resistivity is mainly influenced by the type of soil (loam, shale, etc), moisture content, the amount of electrolyte (mineral and dissolved salts) and finally temperature (climate factor). When designing a grounding system for a specific performance objective, it is necessary to accurately measure the soil resistivity of the site where the ground is to be installed. Probability the most significant short term changes to soil resistivity are causes by recent weather or climate. It is established that up saturation, increased water content of any soil or rock will increased it conductivity. Also the conductivity of soil generally increased with temperature. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Universiti Malaysia Perlis (UniMAP) | en_US |
dc.subject | Grounding system | en_US |
dc.subject | Soil resistivity | en_US |
dc.title | Study effect of climate factor on grounding resistivity around UniMAP campus | en_US |
dc.type | Learning Object | en_US |
dc.contributor.advisor | Nasrul Helmei Halim | en_US |
dc.publisher.department | School of Electrical System Engineering | en_US |
Appears in Collections: | School of Electrical Systems Engineering (FYP) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Abstract, Acknowledgement.pdf | 161.46 kB | Adobe PDF | View/Open | |
Introduction.pdf | 70.42 kB | Adobe PDF | View/Open | |
Literature review.pdf | 653.14 kB | Adobe PDF | View/Open | |
Methodology.pdf | 1.24 MB | Adobe PDF | View/Open | |
Results and discussion.pdf | 140.48 kB | Adobe PDF | View/Open | |
Conclusion.pdf | 55.93 kB | Adobe PDF | View/Open | |
Reference and appendix.pdf | 226.46 kB | Adobe PDF | View/Open |
Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.